Specifications
Technical specifications
8.1 SCALANCE X414-3E and X408-2 - technical specifications
SCALANCE X-400 BA
128 Operating Instructions, 03/2009, C79000-G8976-C186-07
SCALANCE X414-3E SCALANCE X408-2
Overvoltage protection at input Non-replaceable fuse (F 3.15 A /
250 V)
Non-replaceable fuse (F 3 A /
32 V)
Digital Inputs Input voltage:
• Rated value 24 V DC safety
extra-low voltage (SELV)
• For state "1": + 13 V ...+ 30 V
• For state "0": – 30 V... + 3 V
Max. input current: 8 mA
Max. cable length: 30 m
Inputs isolated from electronics.
Inputs not present.
C-PLUG
SCALANCE X414-3E SCALANCE X408-2
Dimensions (width x height x
depth)
24.3 x 17.0 x 8.1 mm 24.3 x 17.0 x 8.1 mm
Weight approx. 5 g approx. 5 g
Power consumption 0.015 W 0.015 W
Memory capacity 32 Mbytes 32 Mbytes
Permitted cable lengths
SCALANCE X414-3E SCALANCE X408-2
TP cable length With TP cord up to 10 m, with
FastConnect cabling system up
to 100 m.
With TP cord up to 10 m, with
FastConnect cabling system up
to 100 m.
Redundancy reconfiguration times
Redundancy Reconfiguration times
HSR 300 ms
Standby link 300 ms
MRP 200 ms
Cascading depth
SCALANCE X414-3E SCALANCE X408-2
Linear/star structure Any (only depending on signal
propagation time)
Any (only depending on signal
propagation time)
Ring with redundancy manager
in HSR mode
50 (for reconfiguration time <
0.3 seconds)
50 (for reconfiguration time <
0.3 seconds)