Specifications

Configuration / project engineering
6.4 Operator controls
SCALANCE X-400 BA
110 Operating Instructions, 03/2009, C79000-G8976-C186-07
Switch Status Meaning
OFF SCALANCE X414-3E is not a redundancy manager. RM
ON SCALANCE X414-3E is a redundancy manager.
- - No function.
R1 OFF
R2 OFF
Ports in slot 5 (gigabit ports) are ring ports.
R1 ON
R2 OFF
Ports 1 and 2 of slot 6 are ring ports.
.
R1 OFF
R2 ON
Port 1 of slot 6 is first ring port.
Port 1 of slot 7 is second ring port.
R1 ON
R2 ON
Ring redundancy configurable only by software (CLI, WBM).
Default: No ring redundancy.
When shipped from the factory, all DIL switches are set to OFF.
Ring ports on slots 5 to 7
NOTICE
When supplied, the DIL switches R1 and R2 on the SCALANCE X414-3E are set to OFF.
As a result, the gigabit ports on slot 5 are defined as ring ports and ring redundancy is
therefore enabled. In this case, you cannot enable rapid spanning tree / spanning tree.
For more detailed information, refer to the configuration manual "SCALANCE X-300
SCALANCE X-400 Industrial Ethernet Switches".
If R1 and R2 are set to OFF, the two gigabit ports of slot 5 are selected as ring ports.
Note
If the SCALANCE X414-3E is operated without media modules, R1 and R2 must be set to
OFF, otherwise ports in slots 6 and 7 will be defined as ring ports that are only available
when media modules are plugged in.