Specifications

Configuration / project engineering
6.4 Operator controls
SCALANCE X-400 BA
Operating Instructions, 03/2009, C79000-G8976-C186-07
109
Configuration options
Below the labeling strip on the CPU module on slot 4, there are four DIL switches. These DIL
switches can have one of two states (
ON
/
OFF
).
Figure 6-2 Power module, digital inputs and CPU module with operator controls on the SCALANCE
X414-3E
The RM switch allows you to configure the SCALANCE X414-3E as a redundancy
manager in a ring. When using a SCALANCE X408-2, this setting is made in the software
or using the SELECT/SET button.
The STBY switch is reserved for future functionality and does not currently have any
function.
With switches R1 and R2, you can specify either the two ports in slot 5, the two ports in
slot 6 or the first ports of slots 6 and 7 as ring ports. If you want ring redundancy to be
configured only by software (CLI, WBM), set both switches to ON.