Specifications
Configuration / project engineering
6.4 Operator controls
SCALANCE X-400 BA
108 Operating Instructions, 03/2009, C79000-G8976-C186-07
6.4 Operator controls
6.4.1 DIL switches of the SCALANCE X414-3E
Meaning of the DIL switches
The RM switch allows you to configure the SCALANCE X414-3E as a redundancy manager
in a ring with redundancy manager.
Note
Only the SCALANCE X414-3E basic device has DIL switches.
Ring redundancy can be configured with these DIL switches. If both switches R1 and R2 are
set to ON, ring redundancy can only be configured by software (CLI, WBM). These settings
can only be made in the software for the SCALANCE X408-2 basic device. On the
SCALANCE X408-2, the RM can also be enabled / disabled with the SET/SELECT button.
For more detailed information, refer to the configuration manual "SCALANCE X-300
SCALANCE X-400 Industrial Ethernet Switches".
Changing the switch settings during operation causes fault displays and activates the
signaling contact. The settings are adopted only after the device is restarted.