Specifications

Configuration / project engineering
6.3 Factory default
SCALANCE X-400 BA
Operating Instructions, 03/2009, C79000-G8976-C186-07
107
RM
is set to OFF. This means that the redundancy manager function is disabled.
- -
no function.
R1, R2
are set to OFF. Both (electrical) gigabit ports on slot 5 are defined as ring ports.
Note
There are no DIL switches on the SCALANCE X408-2 basic device. The settings for RM,
SB snd R1, R2 (ring ports) can be made in the software. The RM can also be enabled /
disabled with the SET/SELECT button.
The default settings for RM and ring ports are the same for the SCALANCE X414-3E and
SCALANCE X408-2 basic devices.
Further device properties
With R1 and R2, ring redundancy is enabled when the device ships.
NOTICE
In this mode, RSTP / STP cannot be activated.
C-PLUG
When delivered, the C-PLUG is empty and is initialized with the factory settings when first
started up. All subsequent configuration changes are automatically adopted in the internal
memory of the IE Switch X-400 and in the C-PLUG.