Specifications

Connecting
5.1 Ports
SCALANCE X-400 BA
104 Operating Instructions, 03/2009, C79000-G8976-C186-07
13. Close the cover and turn the
locking mechanism with your hand as
far as possible in the direction of the
arrow.
14. Insert a 2.5 mm screwdriver into the
hole in the locking mechanism and
continue turning it as far as the limit
stop.
15. The connector is correctly locked
when the opening of the locking
mechanism is at the side and the side
edges are flush with the connector.
Notes:
Replace the knife cassette if the cut is
not clean or after stripping
approximately
- 1500 cables with a PVC outer jacket
- 150 cables with a PUR outer jacket
The insulation piercing contacts of the
FC RJ-45 plug can be released and
recontacted up to 10 times.
Cable ends that have had a connector
fitted, must not be used twice but must
be cut off before fitting a new
connector.
To assemble a cable with crossed over
wires, connect the color-coded wires at
one end of the cable in the connector
as shown below:
Connect white with yellow
Connect blue with orange.