Operating instructions
Technical specifications
7.4 SCALANCE X108PoE
SCALANCE X-100
Operating Instructions, 07/2014, A2B00060666-05
51
Technical specifications
Permitted ambient conditions
Ambient temperature
During operation
-20 °C to +60 °C
During storage
-40 °C to +80 °C
During transportation
-40 °C to +80 °C
Relative humidity
During operation
≤ 95 % no condensation
Operating altitude During operation ≤ 2,000 m above sea level at max. 56 °C
ambient temperature
≤ 3,000 m above sea level at max. 50 °C
ambient temperature
Design, dimensions and weight
Immunity to interference
EN 61000-6-2
Emission
EN 61000-6-4
Degree of protection
IP 30
MTBF (EN/IEC 61709, 40 °C)
61.64 years
Housing material
Basic housing
Die cast aluminum, powder coated
Front cover Polyphenylene ether + polystyrene
(PPE+PS plastic)
Weight
550 g
Dimensions (W x H x D)
40 x 125 x 124 mm
Installation options
• Installation on a DIN rail
• Installation on an S7-300 standard rail
• Wall mounting
Switching properties
Aging time
30 seconds
Max. number of learnable MAC
addresses
2048
Response to LLDP frames
Blocking
Response to spanning tree BPDU
frames
Forwarding
QoS priority queues
4
PoE properties
PoE standard
802.3af
Performance
maximum
15.4 W
Note
As of an ambient temperature of 55 °C, there must be a clearance of 40 mm to neighboring
devices on both sides.