Operating instructions

Technical specifications
7.4 SCALANCE X108PoE
SCALANCE X-100
Operating Instructions, 07/2014, A2B00060666-05
51
Technical specifications
Permitted ambient conditions
Ambient temperature
During operation
-20 °C to +60 °C
During storage
-40 °C to +80 °C
During transportation
-40 °C to +80 °C
Relative humidity
During operation
≤ 95 % no condensation
Operating altitude During operation 2,000 m above sea level at max. 56 °C
ambient temperature
3,000 m above sea level at max. 50 °C
ambient temperature
Design, dimensions and weight
Immunity to interference
EN 61000-6-2
Emission
EN 61000-6-4
Degree of protection
IP 30
MTBF (EN/IEC 61709, 40 °C)
61.64 years
Housing material
Basic housing
Die cast aluminum, powder coated
Front cover Polyphenylene ether + polystyrene
(PPE+PS plastic)
Weight
550 g
Dimensions (W x H x D)
40 x 125 x 124 mm
Installation options
Installation on a DIN rail
Installation on an S7-300 standard rail
Wall mounting
Switching properties
Aging time
30 seconds
Max. number of learnable MAC
addresses
2048
Response to LLDP frames
Blocking
Response to spanning tree BPDU
frames
Forwarding
QoS priority queues
4
PoE properties
PoE standard
802.3af
Performance
maximum
15.4 W
Note
As of an ambient temperature of 55 °C, there must be a clearance of 40 mm to neighboring
devices on both sides.