Operating instructions

Technical specifications
7.3 SCALANCE X108
SCALANCE X-100
48 Operating Instructions, 07/2014, A2B00060666-05
Technical specifications
Permitted ambient conditions
Ambient temperature
During operation
-20 °C to +70 °C
During storage
-40 °C to +80 °C
During transportation
-40 °C to +80 °C
Relative humidity
During operation
≤ 95 % no condensation
Operating altitude During operation 2,000 m above sea level at max. 56 °C
ambient temperature
3,000 m above sea level at max. 50 °C
ambient temperature
Design, dimensions and weight
Immunity to interference
EN 61000-6-2
Emission
EN 61000-6-4
Degree of protection
IP 30
MTBF (EN/IEC 61709, 40 °C)
139.83 years
Housing material
Basic housing
Die cast aluminum, powder coated
Front cover Polyphenylene ether + polystyrene
(PPE+PS plastic)
Weight
780 g
Dimensions (W x H x D)
60 x 125 x 124 mm
Installation options
Installation on a DIN rail
Installation on an S7-300 standard rail
Wall mounting
Switching properties
Aging time
30 seconds
Max. number of learnable MAC
addresses
2048
Response to LLDP frames
Blocking
Response to spanning tree BPDU
frames
Forwarding
QoS priority queues
4
Note
The number of SCALANCE X Industrial Ethernet switches connected in a line influences the
frame delay time.
When a frame passes through devices of the SCALANCE X
-100 product
line, it is delayed by
the store and forward function of the switch
with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps)
with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps)
This means that the more devices of the SCALANC
E X-100 product line, the frame passes