Operating instructions

Technical specifications
7.2 SCALANCE X106-1
SCALANCE X-100
Operating Instructions, 07/2014, A2B00060666-05
45
Technical specifications
Optical parameters
Cable type
Multimode glass FO cable, cable cross sections 62.5/125 μm and 50/125 μm
Permitted cable length (glass FO
cable)
Cable cross-section
Permitted cable length
62.5/125 μm
50/125 μm
0 to 4000 m
0 to 5000 m
Attenuation 1 dB/km at 1300 nm
1200 MHz x km at 1300 nm
6 dB max. permitted FO cable
attenuation with
3 dB link power margin
Electrical data
Power supply Voltage range 18 to 32 VDC Safe Extra Low Voltage
(SELV)
Rated voltage
24 VDC
Design
4-terminal plug-in block
Signaling contact
Current
max. 100 mA
Rated voltage
24 VDC
Design
2-pin plug-in terminal block
Current consumption
Typical
150 mA
Power loss at 24 VDC
Typical
3.6 W
Overvoltage protection at input
PTC resettable fuse (0.6 A / 60 V)
Permitted ambient conditions
Ambient temperature
During operation
-10 °C to +60 °C
During storage
-40 °C to +80 °C
During transportation
-40 °C to +80 °C
Relative humidity
During operation
≤ 95 % no condensation
Operating altitude During operation 2,000 m above sea level at max. 56 °C
ambient temperature
3,000 m above sea level at max. 50 °C
ambient temperature
Design, dimensions and weight
Immunity to interference
EN 61000-6-2
Emission
EN 61000-6-4
Degree of protection
IP 30
MTBF (EN/IEC 61709, 40 °C)
136.65 years
Housing material
Basic housing
Die cast aluminum, powder coated
Front cover Polyphenylene ether + polystyrene
(PPE+PS plastic)
Weight 780 g
Dimensions (W x H x D) 60 x 125 x 124 mm