Operating instructions

Technical specifications
7.1 SCALANCE X104-2
SCALANCE X-100
Operating Instructions, 07/2014, A2B00060666-05
43
Technical specifications
Installation options
Installation on a DIN rail
Installation on an S7-300 standard rail
Wall mounting
Switching properties
Aging time
30 seconds
Max. number of learnable MAC
addresses
2048
Response to LLDP frames
Blocking
Response to spanning tree BPDU
frames
Forwarding
QoS priority queues
4
Note
The number of SCALANCE X Industrial Ethernet switches connected in a line influences the
frame delay time.
When a frame passes through devices of the
SCALANCE X-
100 product line, it is delayed by
the store and forward function of the switch
with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps)
with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps)
This means that the more
devices of the SCALANCE X-100 product line, the frame passes
through, the longer the frame delay.
Note
Temperature code for c-UL-us for hazardous locations, FM and ATEX Zone 2
You will find the temperature code "T.." or the maximum ambient temperature
"Ta: .." on the
type plate.