Data Sheet for Product

9
Siemens CE1N4581en
Smart Infrastructure 2020-07-09
Parallel connection
SAS61.. 10 (depending on controller output)
Forced control
Z positioning signal SAS61.. R = 0…1000 Ω, G, G0
R = 0…1000 Ω Stroke proportional to R
Z connected to G Max. stroke 100%
Z connected to G0 Min. stroke 0%
Voltage Max. AC 24 V ±20% /
Max. DC 24 V +20% / -15%
Current draw 0.1 mA
Position feedback
U Voltage range SAS61.. DC 0...10 V
Load impedance > 10 kΩ resistive
Load Max. 1 mA
Connection cables
Wire cross-sectional areas 0.75…1.5 mm
2
, AWG 20…16
2)
Cable entries SAS.. (EU) 1 entry dia. 16.4 mm (für M16)
1 entry dia. 20.5 mm (für M20)
Thread length max. 9mm
SAS..U (US) 2 entries dia. 21.5 mm for ½“ tube connection
SAS61../MO
Fixed connection cable 0.9m
Number of cores 5 x 0.75 mm
2
Protection class
Housing See "Mounting" IP 54 as per EN 60529
Insulation class As per EN 60730
Actuators SAS31.. AC 230 V II
Actuators SAS61.. AC / DC 24 V III
Actuators SAS81.. AC / DC 24 V III
Environmental conditions
Operation IEC 60721-3-3
Climatic conditions Class 3K5
Mounting location Indoors, outdoors
3)
Temperature, general -5…55 °C
Humidity (non-condensing) 5…95 % r. h.
Transport IEC 60721-3-2
Climatic conditions Class 2K3
Temperature -25…70 °C
Humidity < 95 % r. h.
Storage IEC 60721-3-1
Temperature -15…55 °C
Humidity 5…95 % r. h.