Specifications

Differences between FB10 / FB20
01.00|FB20|en
75
FB10/20 switching: output
FB10 FB20 Remark
M_PROG_ACTIVE bio_1_prog_akt Status signal from drive module.
M_BRAKE_ACTIVE bio_1_bremse_fest Status signal from drive module.
M_IN_MOTION bio_1_bewegung_vhr Status signal from drive module.
M_MOTION_BLOCKED
bio_1_mot_blockiert Status signal from drive module.
M_POS_REACHED bio_1_fkt_io If the positioning block has priority, the sig-
nal which is output via "bio_1_fkt_io" is
passed on.
bio_1_fkt_nio In normal execution of the functions, CMD
B0 .. C1, a distinction is made between ex-
ecution OK/NOK. NOK is set if the function
is aborted during its execution.
--- bio_di_01_status Status signal from the digital input of the
drive module.
bio_di_02_status
bio_di_03_status
bio_di_04_status
–- io_fkt_vfs_nr
If the control function has been successfully
completed, the values which were present
at the start of the control start function on
the FB are also given out. This gives the
programmer the additional option to eva-
luate the values in the program, e.g. for the
progression conditions for the sequences.
reo_fkt_sw_i
reo_fkt_sw_pos
M_ACT_VELO reo_iw_v Current speed
M_ACT_CURR reo_iw_i Current electrical current
M_ACT_POS reo_iw_pos Current position