Specifications

AT command set for S45 Siemens mobile phones and modems
_________________________________________________________________________________________
__________________________________________________________________________________________
Siemens Document No.: A30880-A10-A001-3-D376
Revision: 1.8
Revision Date: 30. November, 2001
92
2.4.2.14 AT^SMGO
AT^SMGO SMS overflow indicator
Test command
AT^SMGO=?
Response
^SMGO: (list of supported <n>s)
OK/ERROR/+CMS ERROR
Parameter
<n>
0
Disable
1
Enable
Read command
AT^SMGO?
Response
^SMGO: <n>,<mode>
OK/ERROR/+CMS ERROR
Parameter
<n>
See Test command
<mode> 0
Space still available
1
SMS buffer is full (The buffer for received short messages is
<mem3>. See AT+CPMS command.)
2
Buffer is full and a new message is waiting in SC for delivery
to phone
Write command
AT^SMGO=<n>
Parameter
<n>
See Test command
<mode>
See Test command
Response
OK/ERROR/+CMS ERROR
Unsolicited message
^SMGO: <mode>
Notes
1) Indication during data transfer via break (100ms).
2)
Incoming short messages with message class 1 or 2 (refer <dcs> GSM
03.38) will be stored in the "ME" or "SM" storage only. Therefore, the
AT^SMGO: 2 indication can occur without a preceding AT^SMGO: 1
indication.
2.4.2.15 AT^SMGR
AT^SMGR
Read SMS (without status change from unread to read)
Syntax identical with AT+CMGR
Test command
AT^SMGR=?
Response
OK
Write command
AT^SMGR=<index>
Response
If PDU mode (+CMGF=0) and command are successful:
AT^SMGR:<stat>,[<alpha>],<length><CR><LF><pdu>
Parameter
<pdu>
See the AT+CMGL command
<stat>
See the AT+CMGL command
<length>
See the AT+CMGL command
otherwise:
+CMS ERROR: <err>
<index>
Index of message in selected memory <mem1>