Specifications
AT command set for S45 Siemens mobile phones and modems
__________________________________________________________________________________________
Siemens Document No.: A30880-A10-A001-3-D376
Revision: 1.8
Revision Date: 30. November.2001
65
2.3.9.13 AT+CSCA
AT+CSCA Address of the SMS service center
Test command
AT+CSCA=?
Response
OK
Read command
AT+CSCA?
Response
+CSCA:<sca>,<tosca>
Parameter
<sca>
Service-center address in string format
<tosca>
Service-center address format
Parameter
<sca>
Service-center address in string format
Write command
AT+CSCA=
<sca>[,<tosca>]
<tosca>
Service-center address format
Response
OK/ERROR
2.3.9.14 AT+CSCB
AT+CSCB Select cell broadcast messages
Test command
AT+CSCB=?
Response
+CSCB: (list of supported <mode>s)
Parameter
<mode>
0
Accepts messages that are defined in <mids> and <dcss>
1
Does not accept messages that are defined in <mids> and
<dcss>
Read command
AT+CSCB?
Response
+CSCB: <mode>,<mids>,<dcss>
Parameter
<mode>
See Test command
<mids>
String type; combinations of CBM message IDs
<dcss>
String type; combinations of CBM data coding schemes
Write command
AT+CSCB=[<mode>[,<mids>[,<dcss>]]]