Specifications

AT command set for S45 Siemens mobile phones and modems
_________________________________________________________________________________________
__________________________________________________________________________________________
Siemens Document No.: A30880-A10-A001-3-D376
Revision: 1.8
Revision Date: 30. November, 2001
44
2.3.4.16 AT+CSQ
AT+CSQ Output signal quality
Test command
AT+CSQ=?
Response
+CSQ: (list of supported <rssi>s), list of supported <ber>)
OK/ERROR/+CME ERROR
Parameter
<rssi>
Reception level
0
-113 dBm or less
1
111 dBm
2 - 30
-109 to -53 dBm
31
-51 dBm or more
99
Unknown
<ber>
Bit error rate
0-7
Like RXQUAL values from Table GSM 05.08 in
Section 8.2.4
99
Unknown
Execute command
AT+CSQ
Response
+CSQ: <rssi>, <ber>
OK/ERROR/+CME ERROR
Parameter
<rssi>
See Test command
<ber>
See Test command
2.3.4.17 AT+CVIB
AT+CVIB Vibrator mode
Test command
AT+CVIB=?
Response
+CVIB: (list of supported <mode>s)
OK
Execute command
AT+CVIB
Response
+CVIB: <mode>
OK/ERROR/+CME ERROR
Write command
AT+CVIB=<mode>
Response
OK/ERROR/+CME ERROR
Parameter
<mode>
Vibrator mode
0
disable
1
enable
16
vibrate then ring (not available in every model)