Specifications

AT command set for S45 Siemens mobile phones and modems
_________________________________________________________________________________________
__________________________________________________________________________________________
Siemens Document No.: A30880-A10-A001-3-D376
Revision: 1.8
Revision Date: 30. November, 2001
26
Cont.
Response
If <mode>=2 and command is successful
+CLCK: <status>[,<class1>[<CR><LF>
+CLCK: <status>, class2....]]
OK/ERROR/+CME ERROR
Parameter
<status>
0
Off
1
On
Note:
If no device code (“PS”) has previously been entered, at+clck=ps,2
will return an error.
It is possible to set a new device code or to delete it using the
AT+CPWD command.
2.3.3.7 AT+CLIP
AT+CLIP Display telephone number of calling party
Test command
AT+CLIP=?
Response
+CLIP: (list of supported <n>s)
OK/ERROR/+CME ERROR
Parameter
<n>
0
Suppresses unsolicited messages
1
Displays unsolicited messages
Read command
AT+CLIP?
Response
+CLIP: <n>, <m>,<class>,,<cli validity>
OK/ERROR/+CME ERROR
Parameter
<n>
See Test command
<m> 0
CLIP not booked
1
CLIP booked
2
Unknown
<class> 1
Voice
2
Data
4
Fax
7
Voice, Data and FAX (default)
8
SMS
16
data circuit sync
32
data circuit async
64
dedicated packet access
128
dedicated PAD access
X
combination of some of the above classes, e.g. 255
regroups all classes and 5 regroups Voice and FAX
<cli
validity>
0
CLI valid
1
CLI withheld by originator
Cont. Next page
2
CLI not available due to network