Siemens Mobile Phones Document type: Reference Manual Document ID: A30880-A10-A001-3-D376 AT command set for S45 Siemens mobile phones and modems Release/Version: 1.8 Date: 30.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ Issued by Siemens AG ICmobile Mobile Devices SW Development Data Services Grillparzerstrasse 12a D-81675 Munich Copyright Siemens AG 2001 All Rights Reserved. SIEMENS AKTIENGESELLSCHAFT __________________________________________________________________________________________ Siemens Document No.: A30880-A10-A001-3-D376 Revision: 1.8 Revision Date: 30.
AT command set for S45 Siemens mobile phones and modems __________________________________________________________________________________________ Table of Contents 1 General information........................................................................................................................................ 5 1.3 Abbreviations and glossary ..................................................................................................................... 2 1.4 Notational Conventions........
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ List of Tables Table 2-1: Supported GSM 07.07 commands ..........................................................................................................6 Table 2-2: Supported GSM 07.05 commands ..........................................................................................................
AT command set for S45 Siemens mobile phones and modems __________________________________________________________________________________________ 1 General information This document constitutes the manual reference to the AT command set supported by S45 Siemens mobile phones. 1.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 1.6.2 Related Standardisation documentation The following standardisation documents are related to the current document [1] Digital cellular telecommunications system (Phase 2+);AT command set for GSM Mobile Equipment (ME) (GSM 07.07 version 6.4.0 Release 1997) Reference No.
AT command set for S45 Siemens mobile phones and modems 2 Software interface 2.1 Overview of the supported AT command set This section provides overviews of the supported sets of AT commands, separate for each type of command set. Table 2-1 lists all the supported GSM 07.07 AT commands in alphabetical order, and indicates the type of command as defined in the ETSI GSM 07.07 standard: 07.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ AT+CLVL AT+CMEE AT+CMUT AT+COLP AT+COPN AT+COPS Restriction) Loudspeaker volume level Expanded error messages according to GSM 07.
AT command set for S45 Siemens mobile phones and modems Table 2-2 lists all the supported GSM 07.05 AT commands in alphabetical order, and indicates the type of command as defined in the ETSI GSM 07.05 standard: 07.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ Table 2-3 lists all the supported AT commands for FAX services in alphabetical oder: Command AT+ FBADLIN AT+ FBADMUL AT+ FBOR AT+FCIG AT+FCLASS AT+FCQ AT+ FCR AT+FDCC AT+FDFFC AT+FDIS AT+FDR AT+FDT AT+FET AT+FK AT+FLID AT+FMDL AT+FMFR AT+FOPT AT+FPHCTO AT+FREV AT+FRH AT+FRM AT+FRS AT+FTH AT+FTM AT+FTS AT+FVRFC Function Define or read number of bad lines Define, r
AT command set for S45 Siemens mobile phones and modems Table 2-5 lists all the supported Siemens-specific AT commands in alphabetical oder: Command AT^SACM AT^SBNR AT^SBNW AT^SCID AT^SCKS AT^SCNI AT^SDBR AT^SDLD AT^SGAUTH AT^SICO AT^SLCK AT^SLNG AT^SMGO AT^SMGL AT^SMGR AT^SMSO AT^SNFS AT^SNFV AT^SPBC AT^SPBG AT^SPBS AT^SPIC AT^SPLM AT^SPLR AT^SPLW AT^SPST AT^SPWD AT^SRTC AT^SSTK Function Output ACM (accumulated call meter) and ACMmax Binary Read Binary Write Output card ID Output SIM card status Output ca
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.2 The AT command set GSM mobile telephones and modems can be operated via Remote Control using a serial interface (data cable or infrared connection). Remote control is implemented by means of AT+C commands according to the ETSI GSM 07.07 [1] and GSM 07.05 [2] specifications, as well as several manufacturer-specific AT commands.
AT command set for S45 Siemens mobile phones and modems ATD; ATD>; ATD>; ATDx[;] Dial the dialing string with the voice utility Valid dial modifiers: I restrict AT+CLIR i suppress AT+CLIR) for next call T tone dialing P pulse dialing is ignored The finishing character ”;” indicates to the phone that the call is to be set up with the voice utility. Otherwise, an attempt is made to set up a data call, which the phone immediately acknowledges with ”ERROR”.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ ATV0 Display acknowledgments as numbers ATV1 ATX Display acknowledgments as text Report link with CONNECT only ignore busy signal ATZ can take one of the following values: 1 Report link with CONNECT plus baud rate, ignore busy signal 2 same as ATX1 3 same as ATX, but report BUSY 4 same as ATX, t report BUSY Set to default configuration AT&C Circui
AT command set for S45 Siemens mobile phones and modems Local flow control selection (DTE ↔ DCE); can be customized \Q can take one of the following values: \V[n] 0 Disable flow control 1 2 3 XON-XOFF software flow control CTS only flow control RTS/CTS flow control Modem command 0 No /REL or /RLP appendix with the CONNECT message 1 /REL or /RLP appendix with the CONNECT message Table 2-6: Commands supported according to Hayes standard 2.2.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.1.2 AT+CGMI AT+CGMI Issue manufacturer ID code Test command Response AT+CGMI=? OK Execute command Response AT+CGMI Parameter 2.3.1.3 Name of manufacturer (SIEMENS) AT+CGMM AT+CGMM Issue model ID code Test command Response AT+CGMM=? OK Execute command Response AT+CGMM Parameter 2.3.1.
AT command set for S45 Siemens mobile phones and modems 2.3.1.6 AT+CIMI AT+CIMI Output of IMSI Test command Response AT+CIMI=? OK Execute command Response AT+CIMI Parameter 2.3.1.7 International Mobile Subscriber Identity (IMSI) AT+CKPD AT+CKPD Keypad control Test command Response AT+CKPD=? OK/ERROR/+CME ERROR Write command AT+CKPD=[,
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.1.9 AT+GSN AT+GSN Output the serial number (IMEI) Test command Response AT+GSN=? OK Execute command Response AT+GSN +GSN: Parameter 2.3.1.
AT command set for S45 Siemens mobile phones and modems Test command Response AT+CR=? +CR: (list of supported s) OK/ERROR/+CME ERROR Parameter 0 disables reporting 1 enables reportingOK/ERROR/+CME ERROR Read command Response AT+CR? +CR: OK/ERROR/+CME ERROR Parameter Write command Parameter AT+CR= See Test command See Test command Response OK/ERROR/+CME ERROR 2.3.2.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.3 Network service related commands This section provides the descriptions of commands related to network service. 2.3.3.
AT command set for S45 Siemens mobile phones and modems 2.3.3.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.3.
AT command set for S45 Siemens mobile phones and modems 2.3.3.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.3.5 AT+CLCC AT+CLCC List Current Calls Test command Response AT+CLCC=? OK Execute command Response AT+CLCC [+CLCC: ,,,,,,][ +CLCC: ,,,,, ,[...
AT command set for S45 Siemens mobile phones and modems 2.3.3.6 AT+CLCK AT+CLCK Switch locking on and off Test command Response AT+CLCK=? +CLCK: (list of supported s) OK/ERROR/+CME ERROR Revision to GSM 07.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ Response Cont. If =2 and command is successful +CLCK: [,[ +CLCK: , class2....]] OK/ERROR/+CME ERROR Parameter 0 Off 1 On Note: If no device code (“PS”) has previously been entered, at+clck=ps,2 will return an error. It is possible to set a new device code or to delete it using the AT+CPWD command. 2.3.3.
AT command set for S45 Siemens mobile phones and modems Write command AT+CLIP=[] Parameter See Read command Response OK/ERROR/+CME ERROR Unsolicited message +CLIP: ,,,,, 2.3.3.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.3.9 AT+CNUM AT+CNUM Test command AT+ CNUM=? Read own numbers Response +CNUM: OK/ERROR/+CME ERROR Write command Parameter AT+CNUM +CNUM: [],,[...
AT command set for S45 Siemens mobile phones and modems 2.3.3.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.3.
AT command set for S45 Siemens mobile phones and modems 2.3.3.13 AT+CPOL AT+CPOL Preferred operator list Test command Response AT+CPOL=? +CPOL: (list of supported s),(list of supported s) Parameter the order number of operator in the SIM preferred operator list 2 numeric Read command Response AT+CPOL? +CPOL: , , +CPOL:.....
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.3.
AT command set for S45 Siemens mobile phones and modems 2.3.3.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.3.16 AT+CSSN AT+CSSN Supplementary service notifications Test command Response AT+CSSN=? +CSSN: (list of supported s), (list of supported s) Revision according to GSM 07.07 Version 5.0.
AT command set for S45 Siemens mobile phones and modems 2.3.4 Commands related to mobile equipment control and status This section provides the descriptions of commands related to network service. 2.3.4.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.4.
AT command set for S45 Siemens mobile phones and modems Test command Response AT+CLVL=? +CLVL: (list of supported s) OK Read command Response AT+CLVL? +CLVL: OK/ERROR/+CME ERROR Write command Response AT+CLVL= OK/ERROR/+CME ERROR Parameter 2.3.4.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.4.9 AT+CPBR AT+CPBR Read a telephone-book entry Test command Response AT+CPBR= ? +CPBR: (list of supported s), , OK/ERROR/+CME ERROR Parameter Location number Max. length of telephone number Max.
AT command set for S45 Siemens mobile phones and modems 2.3.4.10 AT+CPBS AT+CPBS Select a telephone book Test command Response AT+CPBS=? +CPBS: (list of supported s) OK/ERROR/+CME ERROR Parameter FD SM ME DC ON LD MC RC SIM fix-dialing phonebook SIM phonebook ME phonebook ME Dialled Calls List SIM (or ME) own numbers (MSISDNs) list SIM last-dialling phonebook ME missed (unanswered received) calls list ME received calls list For a description of telephone-book features, see section 2.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.4.11 AT+CPBW AT+CPBW Write a telephone-book entry Test command Response AT+CPBW=? +CPBW: (list of supported s), ,(list of supported s), OK/ERROR/+CME ERROR Parameter Location number Max. length of telephone number Max.
AT command set for S45 Siemens mobile phones and modems 2.3.4.12 AT+CPIN AT+CPIN Enter PIN and query lock Test command Response AT+CPIN=? OK Read command Response AT+CPIN? +CPIN: OK/ERROR/+CME ERROR Parameter READY SIM PIN SIM PUK PH-SIM PIN PH-SIM PUK SIM PIN2 SIM PUK2 No further input necessary SIM PIN input necessary SIM PUK input necessary Device code (theft protection) input necessary Device code PUK (theft protection) input necessary PIN2, e.g.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.4.13 AT+CPUC AT+CPUC Price per unit and currency table Test command Response AT+CPUC=? OK Read command Response AT+CPUC? +CPUC: , OK/ERROR/+CME ERROR Parameter three-character currency code (e.g. “DEM”) price per unit; dot is used as a decimal separator (e.g. 1.
AT command set for S45 Siemens mobile phones and modems 2.3.4.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.4.
AT command set for S45 Siemens mobile phones and modems 2.3.5 Extensions of Hayes Standard commands for GPRS This chapter describes all the extensions of the Hayes Standard commands for GPRS.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.6 Commands for GPRS This section provides the descriptions of commands related to GPRS. 2.3.6.
AT command set for S45 Siemens mobile phones and modems 2.3.6.3 AT+CGATT AT+CGATT GPRS attach or detach Test command Response AT+CGATT=? +CGATT: (list of supported s) OK/ERROR/+CME ERROR Parameter indicates the state of GPRS attachment 0 detached 1 attached Read command Response AT+CGATT? +CGATT: OK/ERROR/+CME ERROR Parameter Write command Parameter AT+CGATT=[] See Test command See Test command Response OK/ERROR/+CME ERROR 2.3.6.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.6.
AT command set for S45 Siemens mobile phones and modems 2.3.6.7 AT+CGDCONT AT+CGDCONT Define PDP Context Test command Response AT+CGDCONT=? +CGDCONT: (range of supported s), ,,,(list of supported s), (list of supported s) [+CGDCONT: (range of supported s), ,,,(list of supported s),(list of supported s)[...
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.6.8 AT+CGEREP AT+CGEREP GPRS event reporting Test command Response AT+CGEREP=? +CGEREP: (list of supported s),(list of supported s) OK/ERROR/+CME ERROR Parameter numeric parameter 0 buffer unsolicited result codes in the MT; if MT result code buffer is full, the oldest ones can be discarded.
AT command set for S45 Siemens mobile phones and modems 2.3.6.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.6.
AT command set for S45 Siemens mobile phones and modems Write command (cont.) AT+CGQREQ=[[,[,[,[,[,]]]]]] Parameter See Read command See Test command See Test command See Test command See Test command See Test command See Test command Response OK/ERROR/+CME ERROR 2.3.6.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.6.
AT command set for S45 Siemens mobile phones and modems 2.3.6.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.8 TIA IS-101 commands (“Voice control interim standard for asynchronous DCE”) This section provides the descriptions of other AT commands. 2.3.8.
AT command set for S45 Siemens mobile phones and modems 2.3.9 AT Cellular commands according to GSM 07.05 for SMS GSM 07.05 commands are used for operating the SMS functions of the GSM mobile phone. The GSM module mobile supports the SMS PDU mode. 2.3.9.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.9.4 AT+CMGL AT+CMGL List SMS Test command Response AT+CMGL=? +CMGL: (list of supported s) Revision according to GSM 07.05 Version 4.7.0 Parameter 0 1 2 3 4 REC UNREAD i.e. received messages unread (default) REC READ i.e. received messages read STO UNSENT i.e. stored unsent messages STO SENT i.e. stored sent messages ALL i.e.
AT command set for S45 Siemens mobile phones and modems 2.3.9.6 AT+CMGS AT+CMGS Send an SMS Test command Response AT+CMGS=? OK Write command If PDU mode (+CMGF=0) AT+CMGS= PDU is given: Parameter Length of PDU See AT+CMGL command Message reference Response If sending is successful: +CMGS: If sending is not successful: +CMS ERROR 2.3.9.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.9.
AT command set for S45 Siemens mobile phones and modems Response OK/ERROR/+CMS ERROR __________________________________________________________________________________________ Siemens Document No.: A30880-A10-A001-3-D376 Revision: 1.8 Revision Date: 30. November.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.9.11 AT+CNMI AT+CNMI Notes Display new incoming SMS TA selects the procedure how the receipt of new SMS messages from the network is indicated to the TE when TE is active, e.g. DTR signal is ON. If TE is inactive (e.g. DTR signal is OFF), message receiving should be done as specified in GSM 03.38.
AT command set for S45 Siemens mobile phones and modems Cont. Rules for storing received CBMs depend on the relevant data coding method (refer to GSM 03.38), the setting of Select CBM Types AT+CSCB) and these values: 0 No CBM indications are routed to the TE.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.9.
AT command set for S45 Siemens mobile phones and modems 2.3.9.13 AT+CSCA AT+CSCA Address of the SMS service center Test command Response AT+CSCA=? OK Read command Response AT+CSCA? +CSCA:, Parameter Service-center address in string format Service-center address format Service-center address in string format Parameter Write command Service-center address format AT+CSCA= [,] Response OK/ERROR 2.3.9.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.9.15 AT+CSMS AT+CSMS Selection of message service Test command Response AT+CSMS=? +CSMS: (list of supported s) Revision according to GSM 07.05 Version 5.0.0 Parameter 0 1 NOTE GSM 3.40 and 3.41 GSM 3.40 and 3.
AT command set for S45 Siemens mobile phones and modems 2.3.10 Modem commands This section provides the descriptions of modem commands. 2.3.10.1 AT+CBST AT+CBST Select bearer service type Selects the bearer service with data rate and the connection element to be used when data calls are originated.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.10.2 AT+CRLP AT+CRLP Select radio link protocol parameter for originating non-transparent data call Test command Response AT+ CRLP =? This modem command sets radio link protocol (RLP) parameters used when non-transparent data calls are initiated. This command returns supported values as a compound value.
AT command set for S45 Siemens mobile phones and modems 0 1 2 e.g. TIA/EIA-602 or ITU V.25ter EIA/TIA-578-A this document and EIA PN-2388 (draft) Service Class 1 Vendor-specific The following FAX commands are dummy commands.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.11.2 AT+FBADMUL AT+ FBADMUL Define, read or test number of bad lines Used for FAX class 2 only This command defines the “Copy-Quality-OK” multiplier. The number of lines received with a bad pixel count is multiplied by this number. If the result exceeds the total number of lines on the page the error rate is considered too high.
AT command set for S45 Siemens mobile phones and modems 2.3.11.4 AT+FCIG AT+FCIG Query or set the Local polling id Used for FAX class 2 only Test command Response AT+FCIG=? +FCIG: (max. length of Local Polling ID string) (range of supported ASCII character values) OK Parameter Local Polling ID string, max. length and possible content as reported by test command. Default value is empty string (“”).
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.11.6 AT+FCLASS AT+FCLASS Test command AT+FCLASS=? Select, read or test FAX service class Response +FCLASS: (list of supported s) OK Parameter 0 1 2 Read command Response AT+FCLASS? OK data (e.g. EIA/TIA-602 or ITU V.
AT command set for S45 Siemens mobile phones and modems 2.3.11.8 AT+FDCC AT+FDCC Select service for MO SMS messages This command allows the connected application to sense and constrain the capabilities of the facsimile DCE (=ME), from the choices defined in ITU T.30 Table 2.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.11.
AT command set for S45 Siemens mobile phones and modems 2.3.11.10 AT+FDIS AT+FDIS Query or set session parameters Used for FAX class 2 only This command allows the controlling application to set and constrain the capabilities used for the current session. +FDIS is used to generate DIS or DTC messages directly. +FDIS (and received DIS messages) is also used to generate DCS messages.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ Cont. *) Note: Read command Response AT+FDIS? OK Only the default value needs to be implemented.
AT command set for S45 Siemens mobile phones and modems 2.3.11.12 AT+FDT AT+FDT Data Transmission Used for FAX class 2 only This command requests the ME to transmit a Phase C page. When the ME is ready to accept Phase C data, it issues the negotiation responses and the CONNECT result code to the application. In Phase B, this command releases the ME to proceed with negotiation, and releases the DCS message to the remote station.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.11.14 AT+FK AT+FK Execute command AT+FK Kill operation, orderly FAX abort Used for FAX class 2 only This command causes the TA to terminate the session in an orderly manner. Response OK/ERROR 2.3.11.15 AT+FLID AT+FLID Query or set session parameters Used for FAX class 2 only Test command AT+FLID=? Parameter Local ID string, max.
AT command set for S45 Siemens mobile phones and modems 2.3.11.17 AT+FMFR AT+FMFR Read command AT+FMFR? Request Manufacturer Identification Used for FAX class 2 only Send the model identification to the TA. Response Siemens OK 2.3.11.18 AT+FOPT AT+FOPT Write command AT+FOPT= Set bit order independently Used for FAX class 2 only Model-specific command to set bit order independently of the understanding which is "mirrored" and which is direct.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.11.20 AT+FREV AT+FREV Read command AT+FREV? Identify Product Revision Used for FAX class 2 only This command sends the revision identification to the TA. Response V2.550 OK 2.3.11.
AT command set for S45 Siemens mobile phones and modems 2.3.11.23 AT+FRS AT+FRS Receive Silence Used for FAX class 1 only Write command AT+FRS= This command causes the TA to report an OK result code to the TE after 10 millisecond intervals of silence have been detected on the line. This command is aborted if any character is received by the DTE. The modem discards the aborting character and issues an OK result code.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.3.11.26 AT+FTS AT+FTS Write command AT+FTS= Stop Transmission and Wait Used for FAX class 1 only This command causes the TA to terminate a transmission and wait for 10 millisecond intervals before responding with the OK result code to the DTE.
AT command set for S45 Siemens mobile phones and modems 2.4.1.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.4.2 User-defined commands for controlling the GSM mobile phone Since user-defined commands cannot be implemented according to official syntax, the character string ”+C” is replaced by ”^S” (”^” = 0x5E). In future, if a user-defined command is accepted in the same syntax in GSM recommendations, the command can be addressed using either command string. 2.4.2.
AT command set for S45 Siemens mobile phones and modems 2.4.2.2 AT^SBNR AT^SBNR Binary Read Test command Response AT^SBNR=? ^SBNR: (list of supported s, (list of supported s)) OK/ERROR/+CME ERROR Parameter: see AT^SBNW command see AT^SBNW command Write command Response AT^SBNR=, ^SBNR: ,,1, ^SBNR: ,,2, [...
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.4.2.
AT command set for S45 Siemens mobile phones and modems 2.4.2.4 AT^SCID AT^SCID Output card ID Test command Response AT^SCID=? OK/ERROR/+CME ERROR Execute command Response AT^SCID ^SCID: OK/ERROR/+CME ERROR Parameter 2.4.2.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.4.2.7 AT^SDBR AT^SDBR Database Read Test command Response AT^SDBR=? ^SDBR: (list of supported s) OK/ERROR/+CME ERROR Parameter: Location number stored in the alphabetically-sorted addressbook Write command Response AT^SDBR= [, [^SDBR: , , , [[...
AT command set for S45 Siemens mobile phones and modems 2.4.2.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.4.2.
AT command set for S45 Siemens mobile phones and modems Response Cont. If =2 and command is successful ^SLCK: [,[ ^SLCK: , class2....]] OK/ERROR/+CME ERROR Parameter 0 1 2.4.2.12 Off On AT^SLNG AT^SLNG Language settings Test command Response AT^SLNG=? ^SLNG: (list of supported languages s) Parameter: Integer; language coded according to GSM 03.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.4.2.
AT command set for S45 Siemens mobile phones and modems 2.4.2.16 AT^SMSO AT^SMSO Switch device off Test command Response AT^SMSO=? OK Execute command Response AT^SMSO OK 2.4.2.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.4.2.
AT command set for S45 Siemens mobile phones and modems 2.4.2.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.4.2.23 AT^SPLM AT^SPLM Read the PLMN list Test command Response AT^SPLM=? OK Execute command Response AT^SPLM ^SPLM: numeric ,long alphanumeric ^SPLM:..... OK/ERROR/+CME ERROR Parameter 2.4.2.
AT command set for S45 Siemens mobile phones and modems 2.4.2.26 AT^SPST AT^SPST Play Signal Tone Test command Response AT^SPST =? ^SPST: (list of supported s) OK Write command Response AT^SPST =, OK/ERROR/+CME ERROR Parameter 0 1 2 3 4 0 1 2.4.2.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.4.2.
AT command set for S45 Siemens mobile phones and modems 2.4.3 Summary of all unsolicited messages Table 2-9 lists all unsolicited messages defined, together with their meaning: Message +CBM: Meaning Direct output of the broadcast message.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ AT+CGREG Telephone number of caller For an explanation of parameters see AT+CLIP Direct output of the short message For an explanation of parameters see AT+CNMI Indication that a new message has arrived For an explanation of parameters see AT+CNMI Telephone number of called line For an explanation of parameters see AT+COLP Network registration For an explanation o
AT command set for S45 Siemens mobile phones and modems 2.5 Appendix A 2.5.1 Factory settings made by AT&F ATE1 (only in case of RCCP mode) ATQ0 ATV1 AT+CCWA=0 AT+CREG=0 AT+CLIP=0 AT+COLP=0 AT+CRC=0 AT+CAOC=0 AT+CMEE=0 AT+CPBS=SM (if available) AT+COPS=0 AT+VTS=1 AT+CSCS="GSM" AT+CSSN=0,0 AT^SCKS=0 Reset pending locks (Phone Pin/Puk, Pin2/Puk2 ...
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.5.2 Features of the Telephone book memory Table 2-10 lists the features supported by the telephone book memory. Name FD SM DC (MD) ON (OW) LD ME BD SD MC (MS) RC (CD) BL MB CS RD Description Category Fix-dialing number GSM 07.07 (SIM fix-dialing telephone book) Abbreviate dialing number GSM 07.
AT command set for S45 Siemens mobile phones and modems 2.5.3 Writing to the FDN Phonebook / FDN Replacement Writing to the fixed-dialing number phonebook is protected by PIN2. A sample Write sequence (to e.g.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.5.4 Using special characters in certain commands ( e. g., +CPBR/+CPBW) String parameters like in certain commands (like, for instance, AT+CPBW) should be entered using quotation marks ‘"‘ (Ascii=Windows=GSM=0x22), since the following problems may occur if the quotation marks are left out: - SPACEs (Space, Blank, Ascii=Windows=GSM=0x20) are skipped. E.
AT command set for S45 Siemens mobile phones and modems 2.6 S Registers This section provides the meanings of S registers used in the modem: S Register Function (default values in bold type) S0 The number of rings before the call is answered default: 0 (i. e.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.8 Appendix B 2.8.1 Example for creating / retrieving an organizer entry -vcs object which has to be uploaded: BEGIN:VCALENDAR VERSION:1.0 BEGIN:VEVENT CATEGORIES:ANNIVERSARY DTSTART:19991213T100000 DESCRIPTION:W.
AT command set for S45 Siemens mobile phones and modems -interrogation of the current ,,, at^sbnw? ^SBNW: "vcs",20,2,3 OK description: The current object which is uploaded is an VCS object. It has to be stored on record 20. 2 of 3 packets have already been uploaded.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.8.2 Examples and hints for using GPRS commands 2.8.2.1 Defining and using a Context Definition Id (CID): Every time a CID is used as a parameter for a GPRS command the CID has to be defined first via the AT+CGDCONT command. To retrieve the parameter of a CID the AT+CGDCONT read option must be used. If the response of AT+CGDCONT? is OK only, no CID is defined.
AT command set for S45 Siemens mobile phones and modems 2.8.2.2 Defining Quality of service for a CID Quality of Service (QoS) is a special parameter of a CID which again consists of several parameters. The QoS consists of • the precedence class • the delay class • the reliability class • the peak throughput class • the mean throughput class and is subdivided into "requested QoS" and "minimum acceptable QoS".
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 2.8.3 The GPRS dial command ATD As an alternative to using the GPRS-AT commands it is possible to connect to a GPRS network by using the dial command "atD". There are two GPRS Service Codes for the ATD command. Values 98 and 99. e. g.: ATD*99# CONNECT // establish a connection via service code 99 ATD*99*123.124.125.
AT command set for S45 Siemens mobile phones and modems 3.1 Summary of CME ERRORS related to GSM 07.07 Table 3-1 lists the numbers and meaning of CME errors related to GSM 07.07. Note: Values smaller than 256 are reserved.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 3.2 Summary of CMS ERRORS related to GSM 07.05 Table 3-2 lists the numbers and meaning of CMS errors related to GSM 07.
AT command set for S45 Siemens mobile phones and modems 300 301 302 303 304 305 310 311 312 313 314 315 316 317 318 320 321 322 330 331 332 340 500 512 ME failure SMS service of ME reserved Operation not allowed Operation not supported Invalid PDU mode parameter Invalid text mode parameter SIM not inserted SIM PIN required PH-SIM PIN required SIM failure SIM busy SIM wrong SIM PUK required SIM PIN2 required SIM PUK2 required Memory failure Invalid memory index Memory full SMSC address unknown no network se
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 3.3 GPRS return values issued by AT+CEER Table 3-3 lists the GPRS return values issued by the AT+CEER command in the form ., where x indicates the type of the value returned and y denotes the reason why the call was terminated. Table 3-3 provides the values for the applications handled by AT+CEER (x values).
AT command set for S45 Siemens mobile phones and modems 3.3.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ 3.3.4 Value 0 1 2 3 4 255 GAPI return values issued by AT+CEER (GAPI_LOC_OWN) Meaning Regular deactivation of the call Action temporarily not allowed Wrong connection type Specified data service profile invalid PDP type or address is unknown Undefined Table 3-7: GAPI return values issued by AT+CEER 3.3.
AT command set for S45 Siemens mobile phones and modems 3.4 List of keys implemented for AT+CKPD The following keas are implemented for the AT+CKPD command: Character ’#’ ’*’ 0..
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ CONNECT 14400/RLP 50 Link with 14400 bps and Radio Link Protocol Table 3-10: Result codes __________________________________________________________________________________________ Siemens Document No.: A30880-A10-A001-3-D376 Revision: 1.8 Revision Date: 30.
AT command set for S45 Siemens mobile phones and modems 3.
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ The abbreviations used in Table 3-11 have the following meaning: ZZ ZZ DN BS type of supplementary services dialling number basic service:Voice T Pw time in seconds network password 330 ---0-9 11 16 13 12 19 10 25 24 27 26 21 22 20 ---- Barring services All services string of digits Voice Sms Fax Sms+fax Voice+fax Voice+sms+fax Data circuit asyncron Data circ
AT command set for S45 Siemens mobile phones and modems 4 Index A/ ............................................................................. 10 AT ............................................................................. 10 AT&C........................................................................ 12 AT&D........................................................................ 12 AT&F ........................................................................ 12 AT^SACM...............................
AT command set for S45 Siemens mobile phones and modems _________________________________________________________________________________________ AT+CSMS ...........................................................64, 99 AT+CSQ................................................................... 42 AT+CSSN ...........................................................32, 99 AT+CVIB .................................................................. 42 AT+FAA.........................................................