Configuring the MicroLok Protocol 137
Parameter Description
The Aging Time for TIN mode2 messages. It specifies how long a message should
be stored in the internal table. When the feature is enabled, any TIN mode2 message
received will be stored in an internal table which can be examined by using command
'SQL SELECT FROM ItcsTin2Dup'. If the same message is received within the time
window specified by this parameter, the new message is considered duplicate, and thus
discarded.
Address Aging Timer Synopsis: 60 to 1000
Default: 300 s
The time of communication inactivity after which a learned TIN address is removed from
the device address table. Entries in the Link Statistics Table with the aged address will
be kept until statistics are cleared.
Broadcast Addresses Synopsis: { Static, Dynamic, StaticAndDynamic }
Default: Static
The device address table in which addresses will be found for broadcast messages.
Unicast Addresses Synopsis: { Static, Dynamic, StaticAndDynamic }
Default: Dynamic
The device address table in which addresses will be found for unicast messages.
Link Stats Synopsis: { Disabled, Enabled }
Default: Enabled
Enables link statistics collection for this protocol.
WIN DSCP Synopsis: 0 to 63
Default: 0
To set the DS byte in the IP header. DS byte setting is supported in the egress direction
only.
TIN DSCP Synopsis: 0 to 63
Default: 0
To set the DS byte in the IP header. DS byte setting is supported in the egress direction
only.
4. Click Apply.
Section 5.4.11
Configuring the MicroLok Protocol
To configure the MicroLok protocol for a serial port, do the following:
1. Make sure the serial port is configured to use the MicroLok protocol. For more information, refer to
Section 5.4.5, “Configuring a Serial Port”.
2. Navigate to Serial Protocols » Configure Protocols » Configure MicroLok. The MicroLok form appears.