Specifications
RUGGEDCOM RSG2200
Installation Guide
Chapter 4
Technical Specifications
Operating Environment 31
s
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens
sales associates when determining maximum segment distances.
SFP Gigabit Transceivers
Order
Code
t
Mode
Connector
Type
Cable
Type
(µm)
Tx λ
(nm)
u
Tx
Minimum
(dBm)
v
Tx
Maximum
(dBm)
v
Rx
Sensitivity
(dBm)
v
Rx
Saturation
(dBm)
v
Maximum
Distance
(km)
w
Power
Budget
(dB)
50/125 0.5
FG51
x
MM LC
62.5/125
850 -9 -2.5 -20 0
0.3
11
FG52 SM LC 9/125 1310 -9.5 -3 -19 -3 10 9.5
FG53 SM LC 9/125 1310 -7 -3 -23 -3 25 16
FG54
y
SM LC 9/125 1550 0 5 -23 -3 70 23
t
Operating temperature range of -40 to 85 °C (-40 to 185 °F), unless specified otherwise.
u
Typical.
v
All optical power numbers are listed as dBm averages.
w
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens
sales associates when determining maximum segment distances.
x
Operating temperature range of -10 to 85 °C (14 to 185 °F).
y
Operating temperature range of 0 to 70 °C (32 to 185 °F).
GBIC Gigabit Transceivers
Order
Code
z
Mode
Connector
Type
Cable
Type
(µm)
Tx λ
(nm)
aa
Tx
Minimum
(dBm)
ab
Tx
Maximum
(dBm)
ab
Rx
Sensitivity
(dBm)
ab
Rx
Saturation
(dBm)
ab
Maximum
Distance
(km)
ac
Power
Budget
(dB)
FG71 SM SC 9/125 1310 -9.5 -3 -21 -3 10 11.5
FG72 SM SC 9/125 1310 -7 -3 -24 -3 25 17
FG73
ad
SM SC 9/125 1550 0 5 -23 -3 70 23
z
Operating temperature range of -40 to 85 °C (-40 to 185 °F), unless specified otherwise.
aa
Typical.
ab
All optical power numbers are listed as dBm averages.
ac
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens
sales associates when determining maximum segment distances.
ad
Operating temperature range of -25 to 85 °C (-13 to 185 °F).
Section 4.6
Operating Environment
Parameter Range Comments
Ambient Operating Temperature -40 to 85 °C (-40 to 185 °F) Ambient Temperature as measured from a 30 cm
radius surrounding the center of the enclosure.
Ambient Relative Humidity 5% to 95% Non-condensing