38 EMI and Environmental Type Tests
Section 6.4
EMI and Environmental Type Tests
The RSG2200 has passed the following EMI and environmental tests.
IEC 61850-3 EMI Type Tests
NOTE
• In the case of an all fiber port configuration, this product meets all Class 2 requirements. Otherwise,
all Class 1 requirements are met for copper ports.
• If the unit contains copper ports, the IEC 1613 conformance is Class 1, during which disturbance
errors may occur but recovery is automatic.
• If the unit contains all fiber ports, the IEC 1613 conformance is Class 2, during which no disturbance
errors will occur.
Test Description Test Levels Severity Levels
Enclosure Contact +/- 8 kVIEC 61000-4-2 ESD
Enclosure Air +/- 15 kV
4
IEC 61000-4-3 Radiated RFI Enclosure Ports 20 V/m Note
a
Signal Ports +/- 4 kV @ 2.5 kHz Note
a
DC Power Ports
AC Power Ports
IEC 61000-4-4 Burst (Fast Transient)
Earth Ground Ports
+/- 4 kV 4
Signal Ports +/- 4 kV Line-to-Earth,
+/- 2 kV Line-to-Line
4
DC Power Ports +/- 2 kV Line-to-Earth,
+/- 1 kV Line-to-Line
3
IEC 61000-4-5 Surge
AC Power Ports +/- 4 kV Line-to-Earth,
+/- 2 kV Line-to-Line
4
Signal Ports
DC Power Ports
AC Power Ports
IEC 61000-4-6 Induced (Conducted) RFI
Earth Ground Ports
10 V 3
40 A/m, continuous,
1000 A/m for 1 s
Note
a
IEC 61000-4-8 Magnetic Field Enclosure Ports
1000 A/m for 1 s 5
DC Power Ports 30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
IEC 61000-4-29 Voltage Dips and
Interrupts (DC
Power Ports)
AC Power Ports 30% for 1 period
60% for 50 periods