Specifications
RUGGEDCOM RS8000
Installation Guide
Chapter 4
Technical Specifications
Power Supply Specifications 15
Technical Specifications
The following sections provide important technical specifications related to the device and available modules:
• Section 4.1, “Power Supply Specifications”
• Section 4.2, “Failsafe Relay Specifications”
• Section 4.3, “Copper Ethernet Port Specifications”
• Section 4.4, “Fiber Optic Ethernet Port Specifications”
• Section 4.5, “Operating Environment”
• Section 4.6, “Mechanical Specifications”
Section 4.1
Power Supply Specifications
Input Range
Power Supply Type
Minimum Maximum
Internal Fuse Rating
ab
Maximum Power
Consumption
c
12-24 VDC 10 VDC 36 VDC 6.3 A(F)
24 VDC 18 VDC 36 VDC 5 A(F)
48 VDC 36 VDC 59 VDC 3.15 A(T)
HI (125/250 VDC)
d
88 VDC 300 VDC 3.15 A(T)
HI (110/230 VAC)
d
85 VAC 265 VAC 3.15 A(T)
15 W
a
(F) denotes fast-acting fuse
b
(T) denotes time-delay fuse.
c
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports.
d
This is the same power supply for both AC and DC.
Section 4.2
Failsafe Relay Specifications
Voltage Current
30 VAC 0.3 A
30 VDC 1 A
80 VDC 0.3 A