22. Check the assembled connector with the
microscope.
The connector surface is OK. Slight irregularities at the
edge are of no significance.
23. Clean a contaminated connector with lint-free cloths.
Greater irregularities in the broken edges and irregular
light distribution indicate a damaged connector surface.
24. Repeat the connector assembly.
Note
If you find that the edge breaks are on the increase, the cleave tool should be sent in for
inspection. When used correctly, up to 2000 assemblies are possible.
If you need to return the tool, talk to your Siemens contact.
If you use anti-kink protection...
1. Push the anti-kink sleeve onto the connector as far as
it will go.
2. Close the connector with the dust protection cap until
you require it.