Commissioning Instructions

Appendices
8
34 | 61
A6V11214854_enUS_
c
Obj.
No.
Obj. Name
Obj. Name
Base
Description
Obj.
Identifier
Data
Type
Sig. Type
Unit
Resolution
Max.
Value
Min.
Value
Change
of Value
State No.
State Text
Present
Value
Default
Command
SpC
57
%R%'RHvac
Coo'TCtlC'Pr
SpC_US
PrSpC_US
Present cooling
setpoint_US
2,442
Analog
Value
~
°F
0.1
122
32
0.1
~
~
Null
71.6
58
%R%'RHvac
Coo'TCtlC'S
pCCmf
SpCCmf
Comfort cooling
setpoint
2,191
Analog
Value
~
°C
0.1
50
0
0.1
~
~
Null
14
59
%R%'RHvac
Coo'TCtlC'S
pCCmf_US
SpCCmf_US
Comfort cooling
setpoint_US
2,447
Analog
Value
~
°F
0.1
122
32
0.1
~
~
Null
57.2
60
%R%'RHvac
Coo'SpTRDt
r'SpTR
SpTR
Room
temperature
setpoint
2,180
Analog
Value
~
°C
0.1
50
0
0.1
~
~
Null
0
61
%R%'RHvac
Coo'SpTRDt
r'SpTR_US
SpTR_US
Room
temperature
setpoint_US
2,436
Analog
Value
~
°F
0.1
122
32
0.1
~
~
Null
0
62
%R%'RHvac
Coo'SpTRDt
r'SpTRShft
SpTRShft
Room
temperature
setpoint shift
2,181
Analog
Value
~
K
0.1
10
-10
0.1
~
~
Null
0
63
%R%'RHvac
Coo'SpTRDt
r'SpTRShft_
US
SpTRShft_U
S
Room
temperature
setpoint
shift_US
2,437
Analog
Value
~
°F
0.1
50
14
0.1
~
~
Null
0
64
%R%'RHvac
Coo'AQualR
Col'AQualR
Rs
AQualRRs
Result of room
air quality
2,153
Analog
Value
~
ppm
0.1
3.40E+38
-3.40E+38
0.1
~
~
0
~
65
%R%'RHvac
Coo'TRCol'T
RRs
TRRs
Result of room
temperature
2,154
Analog
Value
~
°C
0.1
3.40E+38
-3.40E+38
0.1
~
~
0
~
66
%R%'RHvac
Coo'TRCol'T
RRs_US
TRRs_US
Result of room
temperature_U
S
2,410
Analog
Value
~
°F
0.1
3.40E+38
-3.40E+38
0.1
~
~
0
~
67
%R%'RHvac
Coo'TCtlH'Pr
SpHCmf
PrSpHCmf
Present comfort
heating setpoint
2,172
Analog
Value
~
°C
0.1
50
0
0.1
~
~
0
~
68
%R%'RHvac
Coo'TCtlH'Pr
PrSpHCmf_
US
Present comfort
heating
2,428
Analog
Value
~
°F
0.1
122
32
0.1
~
~
0
~