Manage application settings
1. On the Home screen, tap , then tap and .
2. If prompted, enter the administrator password.
3. Tap > , and then scroll to the specific setting that you want to turn on/off or
change to a desired Value.
4. Tap to change the setting as desired.
6.7.3 Changing system setup
If you want to change any of your initial setup options that you’ve already
configured during the startup wizard, you can change them later under Advanced
Settings. You can also change some other default system setup options to suit
your own needs. However, we recommend that only installers or experts with
detailed know-how about your thermostat modify the setup options.
Changing basic configurations of the thermostat allows you to change the
equipment type that your thermostat is working together with. The equipment could
be one of the following:
● Gas boiler
● Radiator with valve
● Radiator with pump
● Electric floor heating
● Fan with electric heating
● Floor heating with valve
● Floor heating with pump
● Electric radiator
● Electric boiler
● Generic heating device
If the selected equipment is related to a pump or valve, you can decide whether to
run the pump or valve periodically.
Change basic configuration
1. On the Home screen, tap , then tap and .
2. If prompted, enter the administrator password.
3. Tap > .
4. Tap OK to stop all of your thermostat’s applications. Your thermostat restarts.
5. After the restart is completed, tap Equipment > Adapt.
6. If necessary, tap to scroll through all the listed equipment types and then
choose one as desired.
7. If the equipment is a pump or valve, choose whether to run the pump or valve
periodically by dragging the slider on the screen.
By changing extended configurations, you can:
● Change input assignments. Before you configure or change to another input, it
is strongly recommended that you’ve connected corresponding peripheral
devices to terminal X1 or X2. The input can be:
– Room temperature
– Operating mode switch
The thermostat switches to the OFF mode if you’ve configured the input as
Normally open. For example, if a thermostat in a hotel is configured to
Changing basic
configurations
Changing extended
configurations