User Manual
12
Siemens Datasheet A6V10954418_en--_g
Smart Infrastructure 2020-11-19
Switching outputs (LX, L1, L2)
Relay contacts Switching voltage Max. AC 250 V;
Min. AC 24 V
Switching current Max. 8 A res., 3 A ind.
At AC 250 V Min. 10 mA
Contact life at
AC 250 V
At 5 A res. 1 x 10
5
cycles (guide value)
Insulating strength
Between relay
contacts and coil
AC 5,000 V
Between relay
contacts (same
pole)
AC 1,000 V
Electrical connections
Connections terminals (via baseplate)
For solid wires
For stranded wires
Screw terminals
2 x 1.5 mm
2
1 x 2.5 mm
2
(min. 0.5 mm
2
)
Environmental conditions
Operation
Climatic conditions
Temperature
Humidity
IEC 60 721-3
Class 3K3
0…+45 °C
<85% r.h.
Storage and transport
Climatic conditions
Temperature
Humidity
Mechanical conditions
IEC 60 721-3
Class 2K3
-25…+70 °C
<93% r.h.
Class 2M2
Standards, directives and approvals
EU conformity (CE) A6V101123354
Safety class II as per EN 60 730-1
Degree of pollution 2
Color
Unit front Signal-white RAL 9003
Base Gray RAL 7035
Dimensions 83x104x32 mm