User Manual

Table Of Contents
Overview
Functions
2
A6V11545892_en--_a 9 | 150
Room temperature control via built-in temperature sensor or external room
temperature/return air temperature sensor
Room relative humidity control via built-in humidity sensor (humidity function
can be disabled.)
Min./max. humidity control by shifting temperature setpoint and releasing
contact for dehumidifier/humidifier
Floor heating temperature limitation
Min. and max. supply air temperature limitation
Selection of operating modes via operating mode button
Button lock for all buttons independently (automatically or manually)
Changeover between heating and cooling mode (automatic via local sensor or
bus, or manually)
Parameters protected by password (disabled by default)
Purge function together with 2-port valve
Valve exercising function to prevent gripping
Reminder to clean fan filters
Min. and max. limitation of room temperature setpoint:
Comfort limitation (min. and max. limitation)
Energy saving concept (min. and max. limitation separate for heating and
cooling)
Temporary Comfort mode extension
Green leaf indication function
Display of current room temperature or setpoint in , or both
Application selection via DIP switches or external commissioning software
(ACS, ETS and Siemens smartphone application PCT Go for Android)
Parameter download with external commissioning software (ACS, ETS and
Siemens smartphone application PCT Go for Android)
Reloading factory settings for commissioning and control parameters
1-speed, 3-speed or DC 0...10 V fan control on RDG200KN and RDG260KN
(automatic or manual fan)
Advanced fan control function, e.g. fan kick, fan start delay, selectable fan
operation (enable, disable, depending on heating/cooling mode, or min. and
max. speed setting)
Fan start depending on fan coil temperature (heating) to avoid cool air while
heating
Enabling fan output only in the 2
nd
stage (2-pipe/2-stage)
Switching fan speed from manual to automatic in the dead zone to avoid
energy waste (selectable function)
Swap function for 2-pipe and 2-stage application by switching the 1
st
stage
heating to 2
nd
stage cooling
On 2-pipe/2-stage application, limit the number of heating or cooling sequence
to one
Control of 6-port ball valve for chilled and heated ceiling, DC 0…10 V,
DC 2…10 V and inverted signals DC 10…0 V, DC 10…2 V (RDG260KN)
Control of 6-port ball valve as changeover (On/Off – open/close signal) and
PICV DC 0…10 V for
Chilled and heated ceiling/floor (RDG260KN)
Fan coil application (RDG260KN)
General functions
Setpoints and display
Setting
Fan
Special functions