Siemens Datasheet A6V10889950_i
Smart Infrastructure 2020-01-14
Operating and setting elements
1 2 6543
7
8
9
10
11
12
13
1. Keylock activated 8. Temperature value
2. Timer with delay Off mode 9. Temperature setpoint adjustment
3. Auto fan, fan speed 1, 2, 3 10. Fan mode selection
4. Cooling mode selected 11. Operating mode selection: On, Off, timer with delay
Off
5. Valve output energized 12. Manual heating/cooling changeover
6. Heating mode selected 13. 5 key buttons to adjust setpoints (access control
parameters), fan modes, operating modes,
heating/cooling changeover
7. Room temperature
Type summary
Ordering
Type Stock number Designation
RDF510 S55770-T382 Room thermostat (White) in single pack of 1 unit
RDF510/BP S55770-T383 Room thermostat (White) in bulk pack of 20 units
RDF510/BP.VS S55770-T403 Room thermostat (Silver) in bulk pack of 20 units
RDF510/BP.VB S55770-T404 Room thermostat (Black) in bulk pack of 20 units
RDF510/BP.VG S55770-T405 Room thermostat (Gold) in bulk pack of 20 units
RDF530 S55770-T384 Room thermostat (White) in single pack of 1 unit
RDF530/BP S55770-T385 Room thermostat (White) in bulk pack of 20 units
RDF530/BP.VS S55770-T423 Room thermostat (Silver) in bulk pack of 20 units
RDF530/BP.VB S55770-T417 Room thermostat (Black) in bulk pack of 20 units
RDF530/BP.VG S55770-T424 Room thermostat (Gold) in bulk pack of 20 units
Delivery