Operating Instructions

Operating instructions
Landis & Staefa RAV11…
RAV11… - the temperature controller that allows you to set the ideal room temperature at the time you
want. You can either rely on the factory settings or make settings tailored to your personal needs.
13
12
11
10
9
8
7
4
2
1
24
23
22
21
20
17
14
15
16
18
19
6
5
3
10
15
20
25
30
5
5
10
15
20
25
30
°C
2224Z03E
°C
Battery compartment
for 2 batteries, Typ AA, 1.5 V
Position for 24-hour
time switch AUZ3.1
or weekly time switch
AUZ3.7
Tappet positions
on time switch
Tappet tilted
outward for
normal temperature
Tappet tilted
inward for
economy temperature
Setting knob for
normal temperature
Setting knob for
economy temperature
LED for low
battery indication
Operating mode
selector
Heating periods
according to
tappet settings
on time switch
Continuous
normal temperature
Continuous
economy temperature
Standby with
frost protection
Getting started
The controller is supplied with factory-set switching patterns, switching times and temperatures.
To commission it, proceed as follows:
Remove the black transit tabs from the two batteries.
Check to see if the batterys are in correct position.
The controller switches itself on.
Set the correct time of day (with the weekly time switch check the weekday!). Make readjustments if
necessary.
Set the operating mode selector to the required position (e.g. AUTO
).
Fold up operating instructions again, place them back into the cover and close the cover again.
Do you want to use automatic operation?
Move the operating mode selector to
the position automatic mode. This
ensures heating according to the
patterns set on the time switch.
Do you require continuous normal
temperature?
Move the operating mode selector to
«Normal temperature». This ensures
continuous heating to the normal
temperature.
Do you require continuous economy
temperature?
Move the operating mode selector to
«Economy temperature». This ensures
continuous heating to the economy
temperature.
Do you require continuous standby with
frost protection?
Move the operating mode selector to
«Standby». In that case, heating is
provided only when the room
temperature falls below the preset frost
protection limit (5 °C).

Summary of content (2 pages)