Operating Instructions

82 / 110
Siemens Synco™ living CE1B2740en
Building Technologies Central apartment unit QAX9x3 13.12.2010
You can only set a fault message delay for water/gas leak and CO alarms.
Faults Panic and Emergency do not require settings.
Fault text
Enter the text for faults 1 – 3 that you want displayed when a fault occurs on
the corresponding fault input.
Main menu > Settings > Faults > Fault X > Fault text:
Acknowledge faults
Specify if fault acknowledgement is needed for faults 1 – 3.
Main menu > Settings > Faults > Fault X > Fault ackn:
No The fault does not need to be acknowledged. The fault mes-
sage disappears automatically as soon as the cause is re-
solved (factory setting).
Yes The fault must be acknowledged even after it is resolved to
make the message disappear.
Fault priority
Specify the priorities for fault 1 – 3.
Main menu > Settings > Faults > Fault X > Fault priority:
Urgent Priority for faults putting the plant at risk or when trouble-free
plant operation no longer can be guaranteed.
Not urgent Priority for faults not putting plant operation at risk.
(factory setting)
Fault release
Specify if fault 1 – 3 is released always or only on absence.
Main menu > Settings > Faults > Fault X > Fault release:
Always The fault message is generated when the contact at the fault
input is not in a normal position (factory setting).
If absent The fault message is generated only during absence when the
contact at the fault input is not in a normal position.