Operating Instructions

30 / 110
Siemens Synco™ living CE1B2740en
Building Technologies Central apartment unit QAX9x3 13.12.2010
Activate supervision via external contact (e.g. key switch)
A pulse from an external contact triggers supervision. Supervision "All moni-
tored" is activated either immediately depending on the set supervision delay
(delay set to indefinite "---") or after a set time (see page 67). Windows and
doors open when supervision is activated are exclu
ded from supervision (see
page 29).
Supervision status can be indicated e.g. via LED on the external cont
act to
make sure supervision is active.
"Partially monitored" cannot be activated via external contact.
Activate supervision via handheld control
Press a button on the handheld control to activate "All monitored". Supervision
delay is skipped and all windows and doors open at this time are automatically
excluded from supervision. The central apartment unit sends confirmation to
the handheld control after supervision is activated (see page 92).
A corresponding color pattern on t
he handheld control's LED indicates if su-
pervision is active or not and if windows and doors were open at the time of
activation.
"Partially monitored" cannot be activated via handheld control.
Activate supervision via web
Supervision ("All monitored" and "partially monitored") can be triggered re-
motely via web. Supervision is activated immediately (no delay). Windows and
doors open when supervision is activated are excluded from supervision (see
page 29).
Supervision status can be queried via the web
to make sure supervision is ac-
tive.
General notes
If a supervised window or door is opened during the supervision period, an
associated fault message is triggered and other predefined actions are initi-
ated (with an adjustable message delay for doors).
Fault messages caused by open doors/windows can be disabled by:
Adjusting the supervision type (Inactive/partially monitored/all moni-
tored).
Reactivating an external contact.
– Handheld control.
– Web.
Depending on the setting, this also interrupts triggered, predefined ac-
tions.