Operating Instructions
29 / 110
Siemens Synco™ living CE1B2740en
Building Technologies Central apartment unit QAX9x3 13.12.2010
General
Supervision (QAX913 only)
Trigger supervision at the central apartment unit
Briefly press the Absence/Supervision button to open the supervision win-
dow. This window allows you to select between the following supervision pat-
terns by pressing the Absence/Supervision or the Arrow buttons:
Inactive Supervision function is inactive.
Partly monitored
The windows (rooms) and doors selected in the
"Partly monitored" option lists are supervised.
All monitored
The windows (rooms) and doors selected in the op-
tion lists "All monitored" are supervised.
The supervision window is displayed only if windows or doors are en-
abled for supervision.
See "Release of supervision“ page 68.
When supervised wind
ows and doors are open and supervision is activated,
an associated display reads "Please close or OK?" and a constant signal is
sounded.
During the set supervision delay, you can close the corresponding doors and
windows.
After all supervised windows are closed, the constant signal sound turns into a
beep whose interval doubles during the last 15 seconds of the set supervision
delay.
Supervision delay starts only after all displayed windows are closed.
If supervision delay is set to indefinite, supervision is activated upon closing
the first door (without delay time).
Both doors can be used to activate supervision, where the first door to
be closed triggers supervision.
Bypass open doors and windows
If open doors and windows should not be supervised, a list of all open win-
dows and doors is displayed in a supervision and absence window on the cen-
tral apartment unit along with the following message: "Please close or OK?“
After pressing the OK button, the following warning appears on the central
apartment unit : "Caution! Open windows are not supervised“. Pressing the
OK button again excludes the related windows and doors from supervision.