Operating Instructions
16 / 110
Siemens Synco™ living CE1B2740en
Building Technologies System overview 13.12.2010
Operation of lights and blinds
The lights and blinds can be controlled with the central apartment unit’s soft-
keys.
Prerequisite for this operation is that the light and blind actuators used
have a binding facility for KNX-RF (KRF960, KRF961, Siemens
GAMMA wave or Hager tebis TX radio) or KNX TP1.
Supervisory functions (QAX913 only)
The QAX913 central apartment unit supervises connected door and window
contacts, smoke, gas, CO and water detectors, and switches the correspond-
ing safety shutoff device as needed.
QFP910 water detector
The water detector detects water via 2 contacts and trig-
gers an alarm.
A radio signal is used to pass on the water alarm to the
central apartment unit.
Door/window contact wave AP 260 (radio)
The door/window contacts detect an open door or open
window and transmit this information via radio signal to
the central apartment unit. They can also be used as de-
tached digital inputs (e.g. for monitoring the door of a
domestic freezer).
DELTA reflex smoke detector with smoke detector
module wave UNI M 255
The smoke detector detects instantly the smoke gener-
ated by a fire and sets off an alarm (flashing LED and
acoustic signal on the device, smoke signal via radio to
the central apartment unit).
Remote operation via handheld control (QAX913 only)
A handheld control allows for remote plant operation. Users can configure the
function of each button (supervision On/Off, emergency alarm, panic alarm,
switching group 1 – 8).
AFK914/C01 handheld control
Handheld control allows for remote control of 4 functions
on the QAX913 central apartment unit.
The handheld control sends a radio telegram to the cen-
tral apartment units as soon as the corresponding button
is pressed. The central apartment unit then sends a cor-
responding confirmation telegram to the handheld con-
trol and the LED on the control is lit.