Commissioning Instructions

82 / 134
Siemens Synco™ living CE1C2740en
Building Technologies Commissioning the system 13.12.2010
Main menu > Commissioning > RF connections
> Hager Tebis > Switching groups > Switching group X
Successful dispatch of the respective telegrams is displayed briefly on the
central apartment unit.
For detailed information on commissioning Hager tebis components,
see the documentation on Hager tebis products.
Connect RF repeaters
You can connect up to 3 RF repeaters.
An RF repeater (1 – 3) must previously have been activated in the
basic configuration to be connected (see 48).
An RF re
peater is automatically
switched on as soon as power is applied via
the AC adapter included in the scope of supply.
The LED lights up green for 2 seconds.
In the case of an RF repeater that is already connected, the LED then goes
out. The repeater is ready for operation.
If the RF repeater has not yet been connected, the LED starts to blink green.
The repeater is now ready for connection.
Inform the central apartment unit that you want to connect an RF repeater:
Main menu > Commissioning > RF connections > RF repeater
> RF repeater X > Connect device
Confirm subentry “Connect device“ by pressing the
Menu/ok button. To con-
nect press the binding button on the device to be connected.
F
LED
2707Z18
Press function button F on the RF re-
peater to connect. The LED lights up
green. Release the button when the LED
starts blinking.
F = Function button
LED = Light emitting diode
The binding LED on the RF repeater blinks green and goes out on successful
binding with the central apartment unit. To confirm successful connection, the
central apartment unit beeps. Press the
Menu/ok button to exit the binding
process.
The RF repeater is now connected and runs in normal operation.
If the binding process with the central apartment unit was unsuccess-
ful, blinking of the LED changes to flashing after 1 minute (status indi-
cation of unbound operation).