Building Technologies Commissioning the system 13.12.2010
Connect lighting and blinds control (QAX913 only)
RF adapter plugs and GAMMA wave lighting and blinds actuators can
only be assigned to switching groups set up for the respective function.
See page 29.
The lighting and blinds actuators are switched on as soon as power is applied.
When commissioning GAMMA wave light actuators, a lamp must be
connected. Otherwise, the actuators are not correctly powered, i.e.
they cannot be connected.
On the central apartment unit, select the switching group which you want to
assign actuators:
Main menu > Commissioning > RF connections
> Switching groups > Switching group X > Connect device
Press the
Menu/ok button to confirm subentry “Connect device“. To connect
press the binding button on the device to be connected.
Connect RF adapter plugs KRF960 and KRF961
If the RF adapter plug is not yet connected, the binding LED flashes.
Press the button on the RF adapter plug. The LED lights up permanently. Re-
lease the button when the LED starts blinking. Successful connection is dis-
played on the central apartment unit and confirmed with a beep.
Connect GAMMA wave actuator (QAX913 only)
Press the button on the GAMMA wave actuator until the LED on the actuator
starts blinking (approx. 10 seconds). Successful connection is displayed on
the central apartment unit and confirmed with a beep. The LED on the actua-
tor goes out.
You can connect all actuators of the same switching group without
having enter further information on the central apartment unit.
A switching group can be assigned any number of light actuators as
they are not entered on the device list of the central apartment unit.
When all light actuators of a switching group are connected, close the binding
process by pressing the
Menu/ok button.
The process is required for every switching group.
For detailed information on commissioning GAMMA wave compo-
nents, see the documentation covering the GAMMA wave products.
Connect switching group relay (QAX913 only)
Inform the QAX913 central apartment unit that you want to connect an output
as switching group relay: