Commissioning Instructions

60 / 134
Siemens Synco™ living CE1C2740en
Building Technologies Commissioning the system 13.12.2010
You can connect all devices of the same room, one after the other,
with having to enter additional information on the central apartment
unit.
Continue by switching on all RF devices to be connected to the room and
connect them. The order of connection is free. The only exception are the
SSA955 radiator control actuators and the RRV91… heating circuit controllers
where the control actuator / control channel of the room connected first serves
as the lead controller / lead channel and the other control actuators / control
channels as the lag controllers.
Every connection is displayed and confirmed by a beep. When all devices of a
room / switching group or device class are connected, close the binding proc-
ess by pressing the
Menu/ok button.
Connect room unit QAW910
The room unit is automatically switched on as soon as the batteries are in-
serted.
When the room unit is switched on,
the full display appears for 2 seconds.
If the batteries are almost empty, the
low-battery symbol appears.
As long as the room unit is not con-
nected, the display shows the binding
symbol and the room temperature.
A room unit previously connected changes directly to normal opera-
tion after the full display.
F
2707Z033
Keep pressing multifunction but-
ton F on the room unit until the
binding symbol starts blinking.
Release the button.
F = Function button
The binding symbol on the display of the room unit blinks and goes out after
successful binding with the central apartment unit.