User Manual

7 / 16
Siemens Central apartment unit QAX910 CE1N2707en
Building Technologies 06.01.2009
The different blind positions (fully raised or fully lowered) and different light settings
(on, off, dimming state) can be saved as scenes and retrieved later.
In addition to manual retrieval, the scenes can also be called up via the internal
time switch (time switch can "Always“ be processed or "Only if absent“), presence
simulation or events (e.g. twilight, absence).
Device and system functions
Synco living has a number of inputs and outputs that can be used either via the
universal input / output of the central apartment unit (locally), the universal inputs /
outputs of the RRV912 / RRV918 heating circuit controllers or the RRV934 multi-
controller.
The inputs and outputs can be assigned the following functions:
Inputs
Changeover of operating mode (apartment operating mode and / or DHW oper-
ating mode)
Changeover to summer operation
Heating / cooling changeover
Flow and return temperature sensor
Ventilation contact 1 and 2 (e.g. hygrostat)
Fireplace mode
Triggering the absence function
Twilight function (e.g. by means of a twilight switch) for triggering a switching
group or for enabling presence simulation)
Fault inputs 1 – 8
DHW sensor
Indoor air quality sensor (CO
2
sensor)
Humidity sensor
Outputs
Transmission of heat demand (switching)
Transmission of heat demand (DC 0…10 V)
Switching the room group pump 1 - 2
Primary controller mixing valve 1 - 2
Step switch
HR bypass
Release of kitchen exhaust hood
Release of air conditioner 1 - 12
Transmission of changeover to summer operation
Status output (on / off) for reporting events that can be defined
Window s/ door state output (on / off) for signaling open windows and doors
DHW charging pump / DHW diverting valve
Electric immersion heater
Switching group relays 1 - 8
Fault outputs 1 - 2
The central apartment unit has 8 fault inputs and 2 fault outputs which can be used
via the universal input / output of the QAX910 (locally), the universal inputs / out-
puts of the RRV912 / RRV918 heating circuit controllers or the RRV934 multi-
controller.
Faults of external system components, such as a faulty oil tank level switch, can be
transmitted to the central apartment unit via 8 fault inputs.
Scenes
Inputs and outputs
Fault inputs /
fault outputs