User Manual
7 / 16
Siemens Central apartment unit QAX910 CE1N2707en
Building Technologies 06.01.2009
The different blind positions (fully raised or fully lowered) and different light settings
(on, off, dimming state) can be saved as scenes and retrieved later.
In addition to manual retrieval, the scenes can also be called up via the internal
time switch (time switch can "Always“ be processed or "Only if absent“), presence
simulation or events (e.g. twilight, absence).
Device and system functions
Synco living has a number of inputs and outputs that can be used either via the
universal input / output of the central apartment unit (locally), the universal inputs /
outputs of the RRV912 / RRV918 heating circuit controllers or the RRV934 multi-
controller.
The inputs and outputs can be assigned the following functions:
Inputs
• Changeover of operating mode (apartment operating mode and / or DHW oper-
ating mode)
• Changeover to summer operation
• Heating / cooling changeover
• Flow and return temperature sensor
• Ventilation contact 1 and 2 (e.g. hygrostat)
• Fireplace mode
• Triggering the absence function
• Twilight function (e.g. by means of a twilight switch) for triggering a switching
group or for enabling presence simulation)
• Fault inputs 1 – 8
• DHW sensor
• Indoor air quality sensor (CO
2
sensor)
• Humidity sensor
Outputs
• Transmission of heat demand (switching)
• Transmission of heat demand (DC 0…10 V)
• Switching the room group pump 1 - 2
• Primary controller mixing valve 1 - 2
• Step switch
• HR bypass
• Release of kitchen exhaust hood
• Release of air conditioner 1 - 12
• Transmission of changeover to summer operation
• Status output (on / off) for reporting events that can be defined
• Window s/ door state output (on / off) for signaling open windows and doors
• DHW charging pump / DHW diverting valve
• Electric immersion heater
• Switching group relays 1 - 8
• Fault outputs 1 - 2
The central apartment unit has 8 fault inputs and 2 fault outputs which can be used
via the universal input / output of the QAX910 (locally), the universal inputs / out-
puts of the RRV912 / RRV918 heating circuit controllers or the RRV934 multi-
controller.
Faults of external system components, such as a faulty oil tank level switch, can be
transmitted to the central apartment unit via 8 fault inputs.
Scenes
Inputs and outputs
Fault inputs /
fault outputs