Connect input for open fireplace mode
Inform the central apartment unit that you want to use a universal input B of a
heating circuit controller or a universal input Xx of a multi-controller as an input
for chimney mode:
Main menu > Commissioning > RF connections > Ventilation
> Inputs > Open fireplace mode > Connect device:
Confirm subentry “Connect device“ by pressing the Menu/ok button. To make
the connection, you are then prompted to press the binding button on the
device to be connected.
Use the channel selection button (CH) to select universal input B of the heat-
ing circuit controller or the required universal input Xx of the multi-controller.
The LED of the selected channel blinks. If the selected channel is not yet
connected, the binding LED starts flashing.
Now, press the binding button on the heating circuit controller or multi-
controller. The LED lights up green. When it starts blinking, you can release
the binding button.
A successful connection appears on the display of the central apartment unit
and confirmed with a beep. Close the binding process by pressing the
Menu/ok button.
Connect input for ventilation contacts 1 and 2
Inform the central apartment unit that you want to use a universal input B of a
heating circuit controller or a universal input Xx of a multi-controller or a door /
window contact wave AP 260 as an input for ventilation contact 1 or 2:
Main menu > Commissioning > RF connections > Ventilation
> Inputs > Ventilation contact X > Connect device:
Confirm subentry “Connect device“ by pressing the Menu/ok button. To make
the connection, you are then prompted to press the binding button on the
device to be connected.
If you want to use a universal input B of a heating circuit controller or a univer-
sal input Xx of a multi-controller as an input for a ventilation contact, select it
with the channel selection button (CH) and press the binding button. The LED
lights up green. When it starts blinking, you can release the binding button.
If you want to use a door / window contact wave AP 260 as an input for a
ventilation contact, press the button on the door / window contact for about
1 second. Then, the LED blinks for a few seconds.
A successful connection appears on the display of the central apartment unit
and confirmed with a beep. Close the binding process by pressing the
Menu/ok button.