User Manual
31 / 124
Siemens Synco™ living CE1C2707en
Building Technologies Commissioning the system 23.08.2008
Configure ventilation
The central apartment unit facilitates control of apartment ventilation via the
multi-controller. For the other settings, refer to section “Extra configuration“
and the operating instructions in section “Ventilation“.
I
II III
FOL
AUL
ZUL
ABL
Q1 Q2
Q3
X1
X2
RRV934
2707D112de
RRV934 Multi-controller
Q1 – Q3 3-stage step switch of ventilation plant
X1 Indoor air quality sensor
X2 Humidity sensor
ZUL Supply air
ABL Extract air
AUL Outside air
FOL Exhaust air
Function
Inform the central apartment unit about the number of stages (speeds) of the
fan used for ventilation.
Main menu > Commissioning > Basic configuration
> Ventilation > Function:
Factory setting Your setting
--- --- (inactive – no ventilation installed)
1-stage
2-stage
3-stage