Electric immersion heater
State whether an electric immersion heater is used and how it is controlled.
--- Inactive – no electric immersion heater installed
Via RF Electric immersion heater connected to relay output
Qx of an RRV91… heating circuit controller or
RRV934 multi-controller
Q1 (local) Electric immersion heater connected to relay output
Q1 of the central apartment unit
Main menu > Commissioning > Basic configuration
> DHW > El immersion heater:
Factory setting ---
Your setting ---
Via RF
Q1 (local)
Operation of DHW heating
You can use the central apartment unit for remote control of DHW heating of
some other KNX TP1 device.
--- Inactive – no remote operation of external DHW heat-
ing
Yes without
time switch
Remote control of DHW operating mode and forced
charging of DHW
Yes including
time switch
Remote control of DHW operating mode and forced
charging of DHW. Also, the DHW time switch of the
central apartment unit can override the DHW time
switch of external DHW heating (master / slave)
Main menu > Commissioning > Basic configuration
> DHW > Op external DHW:
Factory setting ---
Your setting ---
Yes, without time switch
Yes, including time switch
Appropriate settings (e.g. DHW zone and time switch slave)are also
to be made on the unit with the DHW heating connection (e.g. the
controller for heat generation). For more detailed information, refer to
the technical documentation of the respective product.