Siemens Synco™ living CE1C2707en
Building Technologies Mounting and installation 23.08.2008
Electrical installation of the
central apartment unit
Installation regulations
• Comply with local regulations (installation, etc.).
• Only qualified staff may carry out electrical installations.
• Prior to installation, disconnect the central apartment unit from power!
• The connection terminals for low-voltage and mains voltage are arranged
on different sides of the unit.
• When wiring the unit, satisfy requirements of safety class II.
• Provide cable strain relief.
Connection terminals / wiring
The connection terminals can be accessed from the front of the base.
Connect the low-voltage and mains voltage cables to the respective terminals
on the base.
Run the cables under the straps provided and – after connection – ensure
strain relief with the help of cable ties.
c d e