User Manual
93 / 110
Siemens Synco™ living CE1B2740en
Building Technologies AFK914/C01 handheld control 13.12.2010
pervision. The blue LED first is lit for max. 2 s; the red LED then briefly blinks
3 times.
A window open at the time of supervision activation can be opened
and closed any number of times (e.g. by wind) without triggering an
alarm.
A door open at the time of supervision activation can be left open
without triggering an alarm. However, the door is supervised as soon
as it is closed.
Supervision delay is off, i.e. all doors and windows are supervised
with immediate effect.
Deactivate supervision:
If supervision is deactivated, the blue LED first is lit for max. 2 s; then the
green LED is lit for 2 s.
Trigger switching group / trigger panic and emergency alarm:
The blue LED is off (after max. 2 s) after receiving the confirmation telegram,
when a switching group, panic or emergency alarm is triggered.
Battery soon empty:
The LED on the handheld control is lit yellow rather than blue if the battery will
soon be empty.