User Manual
67 / 110
Siemens Synco™ living CE1B2740en
Building Technologies Central apartment unit QAX9x3 13.12.2010
Function
“Function” allows you to control switching groups by at random or constant
switch-on of a switching group. The setting is effective only if the presence
simulation of the corresponding switching group as described above is en-
abled.
Main menu > Switching groups > Switching group X
> Presence simulation > Function:
Random The switching group actors are switched on or off within
the set period at random intervals of 3 to 30 minutes.
The first switch-on of each switching group also is at ran-
dom. The switching points of the individual switching
groups differ (factory setting).
Continuously
on
The switching group is switched on constantly. This al-
lows you to ensure that at least one light is on during the
presence simulation.
The settings Release and Function become effective as soon as the central
apartment unit is set to "Absent" via Absence/Supervision button“:
3..30 Min 3..30 Min
Li1
On
Off
B2707Z04
On
Off
On
On
On
Off
Off
Off
FSim
On
Off
t
Li2
On
Off
FSim Simulation release (On, Off)
Li1 Light (On, Off) with function "Random"
Li2 Light (On, Off) with Function "Continuously on"
t Time
The presence simulation is ended as soon as the central apartment unit is set
to "Present".
Supervision (QAX913 only)
Supervision delay
You can set a supervision delay to avoid generating a message upon supervi-
sion activation and simultaneously open window/door.
If supervised windows are open when supervision is activated, a constant
beep is sounded. The Info page Windows/Doors provides information on
which rooms contain open windows or doors.