User Manual

66 / 110
Siemens Synco™ living CE1B2740en
Building Technologies Central apartment unit QAX9x3 13.12.2010
Release
“Release” allows you to control switching groups in dependence of a time
switch or as a combination of time switch and twilight switch.
Main menu > Switching groups > Switching group X
> Presence simulation > Release:
--- Inactive – no presence simulation for this
switching group (factory setting).
With time switch Presence simulation enabled according to
“Time swi presence simulation“.
With time swi + twilight swi Presence simulation enabled according to
“Time swi presence simulation“ and twilight
switch signals DARK.
Example of release according to the time switch:
S'uhr
On
Off
Abw
FSim
ABC D EF
t
On
Off
On
Off
B2707Z01
T’swi Time program presence simulation (On, Off)
Abw Absence (On, Off)
FSim Simulation release (On, Off)
t Time
Example of release according to the time switch and the twilight switch:
Daemm
DA
BR
ABC DE FG
t
B2707Z02
S'uhr
On
Off
Abw
FSim
On
Off
On
Off
T’swi Time program presence simulation (On, Off)
Abw Absence (On, Off)
Daemm Twilight (DA = DARK, BR = BRIGHT)
FSim Simulation release (On, Off)
t Time