User Manual

64 / 110
Siemens Synco™ living CE1B2740en
Building Technologies Central apartment unit QAX9x3 13.12.2010
Twilight switch bright Execution of command when the twilight switch
changes from DARK to BRIGHT.
Twilight switch
Dark + absent
Execution of command when the twilight switch
changes from BRIGHT to DARK and when "Ab-
sence ON”, or when changing from "Absence
OFF” to "Absence ON” and twilight switch sig-
nals DARK.
Twilight switch
Bright + absent
Execution of command when the twilight switch
changes from DARK to BRIGHT and when "Ab-
sence ON”.
Smoke Execution of command when the smoke detec-
tor detects smoke.
Window/door
supervision
Execution of command when window/door su-
pervision is triggered (see page 68).
Water leakage Execution of command as soon as a water leak
is detected.
Gas leakage Execution of command as soon as a gas leak is
detected.
CO alarm Execution of command as soon as a CO alarm is
detected.
Panic Execution of command as soon as a fault input is
triggered via the panic function.
Emergency Execution of command as soon as a fault input is
triggered via the emergency function.
Fault X
(1 – 3)
Execution of command when an event is de-
tected via function fault X (1 - 3) (contact not in
normal position).
Trigger switching groups via handheld control
A switching group function (e.g. switch on/off light, open/close blinds, retrieve
scene) can be triggered via a button on handheld control AKF914/C01. Only
one switching group function (e.g. Light On) can be assigned to a button.
The handheld control does not allow for dimming light and individually
adjust blinds.
Time switch for switching groups
Control of the individual switching groups takes place either manually or ac-
cording to the associated time switch. Available for each switching group are
7 weekdays and one special day, each with up to 8 switching points.
Main menu > Switching groups > Switching group X > Time switch >…
The time switch settings are made analogously to those of the room
time switch (see page 41).