User Manual

21 / 134
Siemens Synco™ living CE1C2740en
Building Technologies Commissioning the system 13.12.2010
Main menu > Commissioning > Basic configuration
> Rooms > Room X > Cooling type:
--- Inactive – all relevant room cooling informa-
tion and operating lines are hidden.
(Factory setting)
Release output For rooms with externally controlled cooling
triggered via a release output.
Air conditioner (S-mode) For rooms with an air conditioner used for
cooling.
Radiator/floor cooling For rooms with radiators or floor heating
used for cooling.
Main menu > Commissioning > Basic configuration
> Rooms > Room X > Supervision only:
--- Inactive – all relevant room information and
operating lines are hidden. (Factory setting)
Active For rooms with no heating or cooling, but
with window contacts or smoke detector to
be supervised.
You can assign an unambiguous room name to every room of the apartment.
The names can also be entered or changed after commissioning.
Main menu > Commissioning > Basic configuration
> Rooms > Room X > Room X:
Predefined room names are provided for quick and easy entry of room
names. You can adjust a predefined room name.