User Manual
Table Of Contents
- 1 About this document
- 2 Commissioning
- 2.1 Default connection
- 2.2 Initial login
- 2.3 Setup wizard
- 2.4 Discover and assign devices
- 2.5 Subscribing to the time master
- 2.6 Time synchronization of the time master
- 2.7 Registering as a foreign device
- 2.8 Touch panel settings
- 2.9 Operating and monitoring features
- 3 Data point integration
- 4 Graphic features
- 4.1 Plant view Tools
- 4.2 Kiosk graphics
- 4.3 Engineering notations
- 5 Graphics Builder
- 5.1 Overview
- 5.2 Pane tools
- 5.3 Graphics libraries
- 6 Graphics engineering
- 6.1 Using supersample graphics
- 6.2 Optimizing graphics for PXM touch panels and standard devices
- 6.3 Thumbnails
- 6.4 Dashboards
- 7 Advanced functionality
- 8 Tips and tricks
- 8.1 Updates required after a time zone change
- 8.2 APPLY BATCH TAGS
- 8.3 Graphic components within models cannot be modified
- 8.4 A graphic with relative binding that includes data points from different branches of the hierarchy cannot be created at the Root level
- 8.5 Relative hyperlinks cannot be added to a graphic at the Root level
- 8.6 Relative hyperlinks in a graphic are broken if the graphic is engineered offline and then imported to another device
- 8.7 Automatic logout from Desigo Control Point causes Graphics Builder to temporarily stop working
- 8.8 Detection of network interruptions
- 8.9 Cancelling a kiosk log out sequence
- 8.10 Special characters do not display in graphic file names
- 8.11 The color of a graphical component may display incorrectly if the component was copied
- Index
Commissioning
Operating and monitoring features
2
A6V11604297_en--_g
27 | 195
5.
(Optional)
Edit the ContentOn filter.
This field defaults to a relative binding filter that applies to the current level of the building hierarchy.
6. Click Add and then OK to clear the message.
Note
The upload process stops if the maximum file size or the maximum memory is exceeded.
The document is now available at the selected location in the building hierarchy.
2.9.9.2 Editing the document file properties
Use this procedure to modify the document name displayed in the Online files list, modify the ContentOn filter,
or to replace the document file.
Editing file properties
1. Select > > Online file management > .
2. Select a document and click Edit.
3. To replace the current document, click Choose file, navigate to the document location on your local
computer and click Open.
4. Edit the Resource name or ContentOn filter if desired.
5. Click Add and then OK to clear the message.
The document file properties have been updated.
2.9.9.3 Removing a document
Use this procedure to remove a document from the Desigo Control Point device.
Removing a document
1. Select > > Online file management > .
A list of documents on the Desigo Control Point device displays.
2. Select the document(s) to remove and click Remove and Yes.
3. Click OK to close the confirmation dialog box.
The selected documents are removed from the device.