User Manual
Table Of Contents
- 1 About this document
- 2 Commissioning
- 2.1 Default connection
- 2.2 Initial login
- 2.3 Setup wizard
- 2.4 Discover and assign devices
- 2.5 Subscribing to the time master
- 2.6 Time synchronization of the time master
- 2.7 Registering as a foreign device
- 2.8 Touch panel settings
- 2.9 Operating and monitoring features
- 3 Data point integration
- 4 Graphic features
- 4.1 Plant view Tools
- 4.2 Kiosk graphics
- 4.3 Engineering notations
- 5 Graphics Builder
- 5.1 Overview
- 5.2 Pane tools
- 5.3 Graphics libraries
- 6 Graphics engineering
- 6.1 Using supersample graphics
- 6.2 Optimizing graphics for PXM touch panels and standard devices
- 6.3 Thumbnails
- 6.4 Dashboards
- 7 Advanced functionality
- 8 Tips and tricks
- 8.1 Updates required after a time zone change
- 8.2 APPLY BATCH TAGS
- 8.3 Graphic components within models cannot be modified
- 8.4 A graphic with relative binding that includes data points from different branches of the hierarchy cannot be created at the Root level
- 8.5 Relative hyperlinks cannot be added to a graphic at the Root level
- 8.6 Relative hyperlinks in a graphic are broken if the graphic is engineered offline and then imported to another device
- 8.7 Automatic logout from Desigo Control Point causes Graphics Builder to temporarily stop working
- 8.8 Detection of network interruptions
- 8.9 Cancelling a kiosk log out sequence
- 8.10 Special characters do not display in graphic file names
- 8.11 The color of a graphical component may display incorrectly if the component was copied
- Index
Commissioning
Discover and assign devices
2
A6V11604297_en--_g
15 | 195
Application fields
Fig. 3: Commissioning wizard, Application fields.
Setting
Description
Application template description
If the device contains multiple applications, select the Application type from the drop-down list.
Active system language
User interface language for the application.
Default: The language selected on the login page.
Object naming convention
Only Hierarchical, standard names (default) applies for Desigo Control Point.
Hierarchical, standard names is a naming format for BACnet objects where names are made up
of room, room segment, etc. For example, %R%'RHvacCoo'TCtlC'SpCCmf, where SpCCmf
(cooling setpoint for comfort) is the BACnet object.
Table 3: Application fields.
2.4 Discover and assign devices
The devices you want to operate and monitor must be assigned to the Desigo Control Point device.
1. Select > Favorite commissioning > Device discovery.
2. Click to activate Edit mode.
3. Click Discover and then click OK to clear the message.
While the system is updating, the work area is cleared and the message No items displays.
4. Select the check box(es) for the discovered device(s) you want to monitor.
5. Click Copy.
6. Select Favorite commissioning > Assigned devices.
7. Click Paste.
8. When you are finished adding devices, click to close Edit mode.
The copied devices are added to the Assigned devices structure and are now available for monitoring.
If you are using a BACnet/IP touch panel, see the
Desigo Touch Panel Clients Commissioning User Guide
(A6V11604303) for procedures to set the screen orientation, define the default graphic that should display after
a power cycle and set up Favorites that can be accessed through the touch panel.