Owner`s manual

11
ProLINE-RoadRunner Operator’s Guide A
Refer to the previous page for the
main menu.
NOTE: Many of the values
shown, such as the Teach and
Network menus, are for
illustration only.
To change languages press Menu
while pressing the Select button.
Arrow Down to the desired
language and press Menu twice.
Socket
Socket 1: Enabled
Socket 2: Enabled
Socket 3: Enabled
Socket 4: Enabled
Adapter Statistics
Reset Clean Count
Clean Count
Clean Alert: 3500
No: 22113204
Mfg: 09/23/02
Actuations:1055
Adptr. Life: 10000
Insertions: 4220
Pass: 4202
Fail: 16
Yld: 99.5
Socket 1
Insertions: 1055
Pass: 1053
Fail: 2
Yield: 99.8
Socket 2 [Same as 1]
Socket 3 [Same as 1]
Socket 4 [Same as 1]
• Light gray shaded fields cannot be
changed.
Operation
Job
Pick Retries: 2
Error Retries: 3
Pocket Pitch: 4
Pocket Advance: 3
Save Air: On
Belt
Clear Belt: On
Buffer: 1
Prefill: Enabled
Warning Msg: On
Head
Velocity: 250
Accel: 700
Probes
Puff: 50
Pick: 200
Place: 100
Travel: 250
Teach
Tape: 40.0
Skt 1: -26.85
Reject: -166
Belt: -180
Restore Defaults
Supervisor Menus Continued