User's Manual
All rights reserved SIMATIC IPC427C
© Copyright Siemens AG 2013
4/5
1)
Suitable for specific LINUX versions in accordance with the specifica-
tions of the Siemens manufacturer’s declaration "Suitable for LINUX",
see http://www.siemens.de/simatic-pc/geeignet-fuer-linux (LINUX is a
trademark of Linus Torvald).
Dimensional drawings (dimensions in mm)
System-tested
SIMATIC Industrial
Software
WinAC RTX (F), WinCC flexible, WinCC
(SCADA as of V7.0), WinCC RT
Advanced and Professional
Approvals
Marine approval
Only for configurations
with CompactFlash or
SSD memory
• GL - Germanische Lloyd
• BV - Bureau Veritias
• LR - Lloyds Register of Shipping
• ABS - American Bureau of Shipping
• DNV - Det Norske Veritas
• NKK - Nippon Kaiji Kyokai
Safety regulations • IEC 61131-2
• IEC 61010-1
• EN 60950-1
Approvals UL508, UL60950, cULus
CE mark • EC Directive 89/336/EEC
(EMC Directive)
• Use in industry:
- Emitted interference: EN 61000-6-4
- Noise immunity: EN 61000-6-2
• Applications in residential areas,
business and trade environments as
well as in workshops:
- Emitted interference: EN 61000-6-3
- Noise immunity: EN 61000-6-1
Dimensions and
weights
Equipment dimensions
(in mm)
• Width x height: 262 x 134
• Depth of basic unit: 47
• Depth of basic unit above rail: 50
• Additional depth per expansion (1-3):
17 each
Weight, approx. 2 kg
46.5
*B67B;;B
133
138
262
52,5
97,5
G_ST80_XX_00456
262
138
© Siemens AG 2013