Operating instructions
Description
3.2 Features
SIMATIC Panel PC 677B
20 Operating Instructions, 05/2007, A5E01035609-01
Monitoring and safety functions
Temperature
• When permitted temperature range is exceeded
• Warning messages from application program that can
be analyzed: local, via LAN (DiagMonitor, optionally
available )
Fans
• Failure of device and power supply fans
• Warning messages from application program that can
be analyzed: local, via LAN (DiagMonitor, optionally
available )
Watchdog
• Monitoring function for program execution
• Restart can be parameterized in the event of a fault
• Warning messages from application program that can
be analyzed: local, via LAN (DiagMonitor, optionally
available )
Transient voltage interruption Up to 20 ms buffer time with full load
Buffer memory Battery-buffered SRAM
Optional accessories
Book mounting bracket For space optimizing installation in switch cabinet
Optional expansions
SIMATIC PC DiagMonitor software
≥ V 3.1
Software tool for monitoring local and remote SIMATIC
PCs:
• Watchdog
• Temperature
• Fan speed
• Hard disk monitoring (SMART)
Communication:
• Ethernet interface (SNMP protocol)
• OPC for integration in SIMATIC software
• Client server architecture
• Layout of log files
SIMATIC PC Image Creator software Software tool for saving data locally
PCI Multi-I/O module Provides one parallel and one serial interface
Software
Operating systems
• Without
• Preinstalled / supplied on Restore DVD:
– Windows 2000 Professional SP4 MUI
– Windows XP Professional SP2 MUI
– Windows XP embedded SP2 English on Compact
Flash